Bit Error Rate Tester (BERT)
Patterns Supported
EIA530
HSU
2-port
V.35
HSU
2-port
EIA530/V.35
HSU
4-port
SRU OCU-DP
2/5/10-port
DS0-DP
4-port
All 1s Yes Yes Yes Yes Yes No
All 0s Yes Yes Yes Yes Yes No
1:1 Yes Yes Yes Yes Yes No
1:7 Yes Yes Yes Yes Yes No
511 Yes Yes Yes Yes Yes No
2047 Yes Yes Yes Yes Yes No
QRSS Yes Yes Yes Yes Yes No
BERT Direction
EIA530
HSU
2-port
V.35
HSU
2-port
EIA530/V.35
HSU
4-port
SRU OCU-DP
2/5/10-port
DS0-DP
4-port
Toward User No No No Yes Yes No
Toward Network Yes Yes Yes Yes Yes No
Statistics Gathered by BERT
EIA530
HSU
2-port
V.35
HSU
2-port
EIA530/V.35
HSU
4-port
SRU OCU-DP
2/5/10-port
DS0-DP
4-port
Bit Errors (BE) Yes Yes Yes Yes Yes No
Errored Seconds (ES) Yes Yes Yes Yes Yes No
Severely Errored Seconds (SES) Yes Yes Yes Yes Yes No
Consecutive Severely Errored Seconds (CSES) Yes Yes Yes Yes Yes No
Out of Synchronization Seconds (OSS) Yes Yes Yes Yes Yes No
Bit Error Rate (BER) Yes Yes Yes Yes Yes No
Elapsed Seconds (ELAP) Yes Yes Yes Yes Yes No
Systems Equipped With Cross-Connect Option
In systems equipped with Cross-Connect CPUs, the cross-connect element adds another level of testing within the
node and enhances the system’s diagnostic capabilities. The operator may also monitor and set the state of the
Transmit and Receive ABCD signaling bits of a digitized voice circuit that is cross-connected between two WANs.
Refer to Table 28 for detailed information.
Table 28—Diagnostic Capabilities of Cross-Connect Circuits
Loop Backs
Local Loop backs
Voice
Without
Singaling
Voice
With
Signaling
Single Data
DS0
(64Kbps)
Super-rate
Data
(Nx64Kbp
s)
Toward WAN1 Yes Yes Yes Yes
Toward WAN2 Yes Yes Yes Yes