- Paradyne Network Device Product Manual

Zhone Technologies, Inc. IMACS Product Book, Version 4
March 2001 Page 30
The 802060 Dual T1 HDSL WAN Card has two ports that that are equipped with 82100 T1 HDSL modules. The
HDSL modules provide 1.544 Mbps T1 transmission over 2 copper pairs. Both modules have to be installed for
proper operation and do not support redundancy. Table 9 depicts the various T1/E1 WAN card specifications. In
addition to the specifications listed in Table 9 (below) the 802060 card is in conformance with ITU-T Q.421 and
ITU-T Q.422. The transmission range is software selectable for the following: 0, 133, 266, 399, 533 or 655 ft. (up
to 200 meters), and CSU (allowing connections to the equipment side of a co-located external CSU over a short
distance, four-wire cable). Software selectable line build out (LBO) settings are also available for all of the
aforementioned transmission ranges.
Table 9—WAN Card Hardware Specifications
Model Number of Ports Number of
Cards
Physical Interface Electrical Interface
800060 1 1 to 4 Through 892xxx I/F
card
811 (T1-DSX/E1-CEPT)
812 (T1-CSU) - 1 per port
801060,
801460
2 1 to 4 Through 892xxx I/F
card
811 (T1-DSX/E1-CEPT)
812 (T1-CSU) - 1 per port
801560 2 1 to 4 Through 892xxx I/F
card
811 (T1-DSX/E1-CEPT)
812 (T1-CSU) - 1 per port
802060 2 1 to 4 Through 892xxx I/F
card
82100 is used to provide 1 T1
HDSL interface
801160 2 1 to 4 Through 892xxx I/F
card
82030 provides 2*1168Kbps E1
HDSL module. Required for each
port.
T1 Signal Format
Electrical Interface
ANSI T1.102/T1.403, DSX-1, balanced 100
Frame Format D4, ESF, Subscriber Loop Carrier (SLC) 96, SLCD4
Line Coding AMI or B8ZS
Signaling AT&T 43801, 62411, ITU-T, Q.421, Q.422 using Robbed-bit method
Error Detection CRC-6, Controlled Slip, Bipolar Violation, Out of Frame
Alarm Indication BellCore TR-TSY-000191
SLIP Limit 126 bits or 138 bits
Bit Rate and Tolerance 1.544Kbps +32PPM. Jitter complies with ANSI T1.403
E1 Signal Format
Electrical Interface
G.703 balanced 120 or unbalanced 75
Coding HDB3
Framing ITU-T G.704 Timeslots consist of 8 bits. Frame consists of 32 time slots,
Multi-frame consists of 16 frames
Signaling CAS, CCS In Timeslot 16 if required.
CAS Signaling protocols: AT&T 43801, 62411, ITU-T Q.421 (2)
Error Detection CRC-4, Controlled Slip, Out of Frame
Alarm Indication ITU-T G.732
Performance and Test Options
Loop backs Line, local, channel, loop back generation and detection
T1 FDL in accordance with AT&T 54016 or ANSI T1.403 (8015 only)
E1 National Bit Supporting (G.704)
Standards Conformance
AT&T TR43801 Digital Channel Bank Requirements & Objectives
AT&T TR54016 Requirements for Interfacing Digital Terminal Equipment to Service
Employing the Extended Superframe Format
AT&T TR62411 Accunet T1.5 Service, Description and Interface Specifications
AT&T TR41449 ISDN Primary Rate Interface Specification
BellCore TR-TSY-000008 Digital Interface Between the SLC 96 Digital Loop
BellCore TR-TSY-000191 Alarm Indication Signal, Requirements and Objectives