2. Verify the possible cause for the “AlAr no rEtE” in chapter H “troubleshoot-
ing”.
3. Rectify the cause of the error, if possible following the advices in chapter H
“troubleshooting”, or alternatively call in a Zibro authorized engineer.
4. Clean the burning pot.
5. Press P4 for longer than 1 second to delete the alarm message from the dis-
play.
6. (Re-)start the stove.
F. MAINTENANCE
The heat, ash and residue produced by the combustion of the re wood makes
regular cleaning and maintenance by both the end user as well as an authorized
technician necessary. Periodically carefully cleaning the stove is important for safe-
ty, effi cient operation and -in the same time- increasing the life time of the stove.
Do not use steel wool, hydrogen chloride or other corrosive, aggressive or scratch-
ing products to clean neither the internal nor the external surface of the stove.
Especially after a prolonged shutdown period the stove and the chimney system
must be checked for any blockages.
F.1 MAINTENANCE TO BE DONE BY THE (END-) USER
Task Frequency
cleaning inner surface of stove Weekly (during season)
cleaning outer surface of stove At your convenience, once per 2 months
cleaning the window pane When dirty
cleaning fumes chamber Every 2 weeks
cleaning the fi re box Every 2 weeks
cleaning the burning pot Before each start up and after every 2
days of burning.
cleaning the ash draw When it is full and before each start
up.
checking the fi re door seal Twice per year, rst time at beginning
of season
cleaning pellet hopper and auger Once per month
The exact cleaning frequency must be intensifi ed when using non optimal quality
pellets.