Stove switches off.
Alarm displayed is
“AlAr dEp”
Fumes extractor is
damaged
Wood pellets can burn thanks to the
chimney flue having natural draught.
Have fan replaced immediately (cod.
Com0259) as it can be bad for your
health. By authorized Zibro technician
only
Possible obstructions of
the combustion air inlet
tube
Clean the fresh air inlet tube. (see
picture 5 in chapter D.7.)
Pressure sensor/switch
is broken
Replaced the pressure switch code
COM0233. By authorized Zibro techni-
cian only
Electronic circuit board
is broken
Replace the electric circuit board code
COM0231. By authorized Zibro techni-
cian only
Stove switches off.
Alarm displayed is
“AlAr dEp”
Excessive chimney
length
Call an chimney expert to verify if the
chimney is according to the law.
Call authorized Zibro technician to
verify whether chimney is suitable for
the stove.
Unfavourable weather
conditions
When there is a very strong wind a
negative depression to the chimney
can occur. Verify and start the stove
again.
Stove switches off.
Alarm displayed is
“AlAr Sic”
Stove is overheated Too high room temperature. Open
doors to other rooms. If the problem
continues call authorized Zibro tech-
nician
Stove is overheated Let the stove cool down and stoke it
again. If the problem continues call
authorized Zibro technician
The room air recircula-
tion fan is broken
Replace the fan, code COM0268. By
authorized Zibro technician only
Temporary power
failure
A voltage failure during the functio-
ning of the stove causes an overhe-
ating of the internal stove. Let the
stove cool down and stoke it again.
Thermostat is broken Replace the thermostat, code
COM0238. By authorized Zibro techni-
cian only
Electronic circuit board
is broken
Replace the electronic circuit board.
Code COM0231 By authorized Zibro
technician only