Installation manual

1
110
Stove switches off.
Alarm displayed is
“AlAr Sec”
Stove is overheated Reset the stove by manual reset but-
ton at back of the stove. Possible
cause: too high room temperature.
Open doors to other rooms. If the
problem continues call authorized
Zibro technician
Stove switches off,
Alarm displayed is
“AlAr HottEmp”
Fumes outlet tempera-
ture sensor is broken
Replace the sensor, Code COM0239.
By authorized Zibro technician only
Electronic circuit board
is broken
Replace the electronic circuit board.
Code COM0231.Call a specialised
technician
The room air recircula-
tion fan is broken
Replace the fan, code COM0268. By
authorized Zibro technician only
Too high parameter
set
Change relative parameter. By autho-
rized Zibro technician only
Stove switches off.
Alarm displayed is
“AlAr Sond”
Fumes outlet tempe-
rature sensor discon-
nected
Verify the sensor is connected to the
circuit board card By authorized Zibro
technician only
Fumes outlet tempera-
ture sensor is broken
Replace the sensor, Code COM0239.
By authorized Zibro technician only
Stove is in steady con-
dition. Display shows
“Stop FirE
The burning pot needs
cleaning
Stove works at minimum rate. Smoke
gas extraction fan works at maxi-
mum rate, no direct problem. Clean
burning put as soon as possible (see
chapter F.3.5)
Stove is in steady con-
dition. Display shows
“Stop FirE
Cold start whem room
air temperature is be-
low 12°C. Ignitor can
not reach the desired
temperature
Use BBQ fire lighter sticks to ignite
the fire. Continue with restart the
stove when the fire lighter sticks are
burning. Follow the normal proce-
dure.
Display shows “ont” Room temperature
below 0°C
Not an error. The thermometer is not
able to measure and display negative
temperatures.
4