Operating instructions

Page 11 of 16 Zip Hydroboil Electronic - Installation & Operating Instructions - 89956 - Feb 2013 v1.07
Configuration mode
The Default configuration for the Hydroboil is as follows.
tting operational modes
To enter Configuration Mode, press and hold the CSS1 and CSS4 for 10
seconds. The unit enters Configuration Mode and the user can configure the
clock as follows.
SET SETPOINT
To return to Normal Mode, press CSS4.
To increment the setpoint, press either CSS2 or CSS3.
To step to the next configuration parameter, press CSS1.
Note 1: The setpoint moves in a circular fashion. It goes from 98 to 99 to 100
to 65 to 66 etc.
Note 2: 100ÂșC may be indicated by 1H or 100 on the LCD
SET CLOCK
To return to Normal Mode, press CSS4.
To increment the Hours, press CSS2.
To increment the Minutes, press CSS3.
To step to the next configuration parameter, press CSS1.
SET DAY-OF-THE-WEEK
To return to Normal Mode, press CSS4.
To step to the next day of the week, press either CSS2 or CSS3.
To step to the next configuration parameter, press CSS1.
SET FILTER EXPIRATION TIME
To return to Normal Operation, press CSS4.
To increment the expiration time, press either CSS2 or CSS3.
To step to the next configuration parameter, press CSS1.
Note 1: The Filter expiration time moves in a circular fashion. It goes from
OFF to 00 to 01 to 02 etc, etc. up to 14 months.
Note 2: 00 is a test mode. When the user returns to Normal Operation, the
CHANGE FILTER icon will appear on the LCD after approximately 1minute. To
clear the CHANGE FILTER icon, the user must re-enter Configuration, set the
Filter Expiration Time to OFF and return to Normal Operation.
Clock display
Day display
Setpoint display
Setting operational modes
(continued)
Filter display