Manual

INPUT CHARACTERISTICS: MRP-6420P
l VOLTAGE: 90 ~ 264 VAC FULL RANGE
l FREQUENCY : 47 ~ 63 Hz
l INPUT CURRENT: 8.0 / 4.0 A FOR 115 / 230 VAC
l INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT REGULATION OUTPUT
MIN.[A] MAX.[A]
PEAK
LOAD LINE
5V 3.0 35 ±
5%
±
1%
50mV
12V 2 20
±
6%
±
1%
120mV
-5V 0 0.5
±
10%
±
1%
150mV
-12V 0 1.2
±
10%
±
1%
150mV
3.3V 1.0 20
±
5%
±
1%
50mV
+5VSB 0.1 2.0
±
5%
±
1%
60mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
REMARKS: * NEITHER +5V & + 3.3V NOR +3.3V & 12V SHOULD EXCEED 48 A
* TOTAL MAXIMUM OUTPUT OF 5V, 3.3V AND 12V : 398W
. TEMPERATURE RANGE : OPERATING 0
0
C --- 40
0
C, STORAGE 20
0
C --- 80
0
C
l HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
l DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
l EFFICIENCY: 63% TYPICAL, AT FULL LOAD
l POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
l OVER POWER PROTECTION: 110 ~ 160% MAX.
OVER VOLTAGE PROTECTION:
+5V à 5.7V ~ 6.6V, 3.3V à 3.9 ~ 4.3V, 12V à 13.0 ~ 14.6V
l EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
l SAFETY: MEET UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
l REMOTE ON / OFF CONTROL
l FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL
l HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
l BALANCE LOAD SHARING DESIGN
l REMOTE SENSING DESIGN
l ISOLATION: BUILT-IN IN THE POWER MODULE
l MEET EN 61000-3-2 CLASS D ( ACTIVE PFC )
l DIMENSION: 86(H) X 150(W) X 185 (D) mm
l COOLING : TWO 40 mm DC FANS (MODULE)
l AC INLET IN EACH MODULE