使用手冊電源供應器機種 HG2, HP2, PSM and PSL Ver. 1.0
規格書
請對照實際購買的產品型號。備註:僅 HG2 機種,在正常使用情形下,產品經 remote-off 遠端
(即以系統面板上的 I/O關機後仍會轉動風扇作二次散熱直至主要零件降溫到適宜的溫度
而停止。此為正常現象,亦是 HG2 機種之特點,可期增長零件壽命。
8 頁,共 14
INPUT CHARACTERISTICS: HG2-6300/6350/6400P
VOLTAGE: 90 ~ 240 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 HZ.
INPUT CURRENT: 6/7/8.0 A (RMS) FOR 115VAC, 3/3.5/4.0 A (RMS) FOR 230VAC.
INRUSH CURRENT: 65A MAX. FOR 115 VAC, 125A MAX. FOR 230 VAC.
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT(A) REGULATION OUTPUT
MIN. MAX. PEAK LOAD LINE
5V 3 35
±
5%
±
1%
50mV
12V 2
22/26/30
+7%/-5%
±
1%
120mV
-5V 0 0.8
±
5%
±
1%
150mV
-12V 0 1.0
±
5%
±
1%
150mV
3.3V 1 25
±
5%
±
1%
50mV
+5VSB 0.1 2
±
5%
±
1%
50mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
REMARK (去掉 S): OUTPUT CURRENT OF 5V & 3.3V COMBINED SHOULD NOT EXCEED 45A.
SPECIFICATION:
TEMPERATURE RANGE: OPERATING 0 --- 40℃.
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE.
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND.
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND.
EFFICIENCY: 68% TYPICAL.
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms.
OVER LOAD PROTECTION: 130 +/- 20%.
OVER VOLTAGE PROTECTION:
+5V 5.7V ~ 6.5V, 3.3V 3.9 ~ 4.3V, 12V 13.6 ~ 15V.
SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V.
EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B.
SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950.
REMOTE ON / OFF CONTROL.
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE / ENABLE ALL
OUTPUT VOLTAGES (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUT VOLTAGES WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUT VOLTAGES WERE DISABLE.
3.3V / 5V REMOTE SENSING.
COOLING: ONE 80mm DC BALL BEARING FAN.
DIMENSION: 140 (D) x150 (W) x 86 (H) mm (PS/2).
ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D.
ADVANCED THERMAL & ACOUSTICS CONTROL FEATURES.