User Manual

INPUT CHARACTERISTICS: R2G-6350P
l VOLTAGE: 90 ~ 264 VAC FULL RANGE
l FREQUENCY : 47 ~ 63 Hz
l INPUT CURRENT: 8.0 / 5.0 A FOR 115 / 230 VAC
l INRUSH CURRENT: 60A / 80A MAX. FOR 115 / 230 VAC PER POWER MODULE
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT REGULATION OUTPUT
MIN.[A]
MAX.[A]
PEAK(A)
LOAD LINE
5V 3.0 35 ±
5%
±
1%
50mV
12V 2 22
±
5%
±
1%
100mV
-5V 0.1 0.5
±
10%
±
1%
150mV
-12V 0.1 0.8
±
10%
±
1%
150mV
3.3V 1.0 20
±
5%
±
1%
50mV
+5VSB 0.1 2.0
±
5%
±
1%
50mV
OUTPUT
VOLTAGE
RIPPLE & NOISE
MAX. [P-P]
REMARKS: TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 35 A
TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 328 W
. TEMPERATURE RANGE : OPERATING 0
0
C --- 40
0
C, STORAGE 20
0
C --- 70
0
C
l HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD NORMAL INPUT VOLTAGE
l DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE
l EFFICIENCY: 63% TYPICAL, AT FULL LOAD
l POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
l OVER LOAD PROTECTION: 110 ~ 160% MAX.
OVER VOLTAGE PROTECTION:
+5V à 5.7V ~ 6.7V, 3.3V à 3.7 ~ 4.7V, 12V à 13.0 ~ 15.0V
. SHORT CIRCUIT : 5V,12V, 3.3V, AUTO-RECOVERED : 5VSB, -5V, -12V
l EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
l SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
l REMOTE ON / OFF CONTROL
l FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL
l HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
l N + 1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL
l REMOTE SENSING DESIGN
l ISOLATION: BUILT-IN IN THE POWER MODULE
l MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC )
l DIMENSION: 82(H) X 101(W) X 300 (D) mm, 276mm -- W/O REAR DC FAN
l COOLING : TWO 40 mm DC FANS ( ONE IN EACH MODULE )
l ONE 80 mm DC FAN ( REAR SIDE )
l I2C FEATURES ( OPTIONAL )