PRODUCTS MANUAL R3G SERIES 2 + 1 Redundant Power Supply
INDEX 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.
1.1 INTRODUCTION First of all, thank you for purchasing R3G Series – 2 + 1 Redundant power supply, the R3G is a 2+1, Hot-swappable/Hot-pluggable, Redundant power supply set, it consists of: (1) complete metal frame (nickel-plated) (2) 2 + 1 compact size power modules (3) backplane board The R3G Series hot swappable redundant power supply offer a maximum 650 watts of output power.
1.2 PACKING Your R3G box package should consist of the following: (A) R3G *1 (B) Accessory pack (included one holding bracket for shipment)*1 (C) Products’ manual *1 1.3 MODEL DESIGNATION Model number identification: R3G – 6650P R3G 6 650 P --- 2 + 1 Redundant Power Supply for 3 U (AC Input) --- for 6 DC outputs (5V/12V/-5V/-12V/3.3V/5VSB) for ATX12V / EPS12V Spec. --- total output power, 650 (unit: watt) --- P for built in PFC (full range).
1.
1.8 INSTALLATION & TESTING Turn off (Remote off) the on/off switch. Mount the power supply in the system chassis using the proper mounting tool, the mounting holes in the power supply should match up with those in the case. Attach the connectors to the M/B by following the M/B instructions, there are various on connectors / pinouts in both power supply and M/B. They should match each other; otherwise the connection will cause undetectable harms.
If everything works out fine, then turn off (remote off) the power system, now put back the cover of the case and tighten with the screws which you have retained earlier. Now you have completed the installation of the R3G redundant power supply system. 1.9 HOT SWAP PROCEDURES Please refer to the following when one power module found defective. A) Locate the defective power module by examining the individual LED (if LED without light, it indicates the power module is defective).
E) Check the LED of the power module lit Green. F) Check the LED which indicates the total power system status, that should be from twinkle to Green. G) Tighten the screws of bracket which hold the power modules to fix it. H) If you want to test this new power module in simulating defective situation. Please refer to the Section 1.8 Installation & Testing Section. 1.
1.11 TROUBLE SHOOTING If you have followed these directions correctly, there should be no problem occurred. Some common symptoms are: the system doesn’t work, buzzer sound, work for a very short period, etc., please try the following steps to verify and correct it: 1. Check all the connections (correct pinouts, loose connections, wrong direction, etc). 2. Check for short-circuits or defective peripherals by unhooking each peripheral once at a time.
The “RELIABILITY “ solution to E-application 新巨企業股份有限公司 ZIPPY TECHNOLOGY CORP. POWER DIVISION HEADQUARTERS 10F, NO. 50, MIN CHYUAN RD., SHIN-TIEN CITY, TAIPEI HSIEN, TAIWAN, R.O.C. TEL: 886 2 2918-8512 FAX: 886 2 2913-4969 WEB SITE: http://www.zippy.com.tw EMAIL: power@zippy.com.tw USA OFFICE 961 CALLE NEGOCIO, SAN CLEMENTE, CA 92673, USA TEL: 949 366 9525 FAX: 949 366 9526 EMAIL: zippy@zippy.