Installation Guide

21
Gas Conversion Procedure
INSTALLATION
STEP 2: SURFACE BURNERS
1. To replace the orifices of the surface burners, lift up the burners and unscrew the
orifices shipped with the range using a 7 mm socket wrench.
2. Replace orifices using the conversion set supplied with the range. Each orifice has a
number indicating its flow diameter printed on the body. Consult the tables starting on
page 18 for matching orifices to burners.
NG = Natural Gas
LPG = Liquid Propane Gas
NG LPG
7 mm
7 mm
Step1
Step 2
Step 3
Step 4
Step 5
NOTE: For the dual burner, the orifice is located on the side of the burner. Use a 7 mm
boxed end wrench to remove and tighten.
Scan to follow along with a video.