Specifications

output level of the selected patch. This may be necessary to compensatc:
for changes
in
total outpul level rtsulting from your parameter settings.
This gives you control over changes in output level that may occur whcn
vou switch patches tvhile performing.
(1)
Use the CURSOR keys to move the effect mark all the way to the right of
SFX
or to the left of'COMP. The bars undcr the
PEAKIBALANCEIPAT-
TERN
display section ~vill show output level, as will the readout. Or you
can
go directly to the output level adjustment mode by pressing the
currently selected PATCH key again.
(2)
Ad just the control above
t
hc
PEAK/BALANCG/PATTERN
display
section. Output level is adjustable over
n
range of
10
to
99.
as shown in the
parameter
\.slue
readout.
Noise reduction(NR) adjustment
Finally, adjust the noise reduction.
NR
lowers the noise during standby.
it can be adjusted and stored for each patch.
(1)NR
is adjustable over a range of
0
to
7,
as shown in the parameter
value readout, with the data slider on the left. Raise the sliderhalue
until the noise lowers to acceptable level.
Patch
storage
To
saw
>-our
cditcd
effect patch, follotv these steps.
(1)
Press the STORE key once.
The
selected
BANK
number and patch
LED
will flash
to
indicate that you are in the storage
node.
(2)
Usc the
RANK
and
PATCIH
keys to select the user bank number and
patch into which you wish to save the sound. (You cannot use a factor?;
preset bank to store edited sounds.)
(31
At
[his point you can still press the
CANCEL
key to cancel the storage
mode and rcturn
to
the state that
existed
before
you
pressed the STORE
key. If you do not wish to cancel, go on to step
4,
below.
(4)
Press
the
STORE key
again
and
the
BANK
number
and patch LED will
stop flashing and remain lit. This confirms storage.
Pre-loaded patch data recall
To load the factory pre-load data into the user banks again,
t~~rn the power off,
then hold the
STORE
key down and turn the power on again, All
40
factory
pre-load data will
be
loaded into the user patch memories.
N0TE:With this operation, all patches you have stored will be lost.
Necessary patch data should be kept with a memo in the blank patch chart.