Owner's manual

INSTALL INSTRUCTIONS
The2GIGDW10345isaThinDoor/WindowContactthatcanbeinstalledondoors,windows,andmanyotherobjectsthatopenandclose.
ThesensortransmitssignalstotheControlPanelwhenamagnetmountednearthesensorismovedawayfromorclosertothesensor.The
sensorhasanex
ternalinputthatacceptsN/Cdrycontactdevices.Thesensorisalsoequippedwithacovertamperforadditionalsecurity.
Box Contents
•D/WSensor
•Magnet
•2Screws
•3MTape
•12WireLead
Programming
Thefollowingstepsareforprogramming(learning)thesensor(2GIGDW10345)intothe2GIG
ControlPanel.Scrollbetweenoponsusingthe←and→arrows.Movetothepreviousornext
promptbypressingthe↑and↓arrows.
1 SelectRFsensor#(01to48).AssigntheDW10toanewzone.
2 SelectRFsensortype.
(01)Entry/Exit1
(02)Entry/Exit2
(03)Perimeter
(23)noresponsetype
3 SelectRFequipmenttype.
(1)contact
4 SelectRFsensorequipmentcode.Enter0862fortheDW103452GIGThinDoor/WindowContact.
5 EnterRFsensorserialnumber(7digits).
ManualEntry:Typeinthelast7digitsoftheTXIDthatisfoundoutsideoftheboxoronthebackofthedevice.
AutoEntry:WiththepanelinLearninmode(pressShiftthenLearn)pulltheBatteryPullTabout.Th
ecorrectTXIDshouldappear.
AcceptthecorrectTXIDbypressingok.
Remember to press the arrow to connue going through the 2GIG system conguraon prompts.
6 SelectRFsensorequipmentage(0to1).
(0)new(productisnew)
(1)existing(productalreadyexists)
7 SelectRFsensor1loopnumber(1to3).
(1)UsesLoop1
(2)UsesWireleadLoop2
(3)UsesExteriorSwitch(magnetonly)
8 SelectRFsensor1dialerdelay.
(0)disabled
9 ConstructRFsensorvoicedescriptor.PressInsertthenpressanynumberbetween002and255toaddaword.Forexample,ifyou
wantedtonamethisDW10as“masterwindow,pressInsertthenpress140forMASTER.PressInsertthenpress251forWINDOW.
10 SelectRFsensorreports(0to1).
(0)disabled
(1)enabled
11 SelectRFsensorsupervised(0to1).
(0)disabled(sensordoesnotreportlossofsupervisionorlowbattery)
(1)enabled(sensorreportslossofsupervision)
12 SelectRFsensorchime(0to13).
(0)disabled(panelwillNOTchimewhensensorisactivated)
(113)enabled(selectsavoiceand/orchimetosoundwhensensorisactivated)
13 Toprogramanothersensorclicknext.
14 Toexitprogramming,clickskipthenendandexit.Uponexit,thepaneltakesaseveralsecondstoreboot.
Testing
•OpentheDoor/WindowContact(separatethemagnetfromthesensor).ThisactioncausestheControlPaneltodisplaytheopenzone
withtheassigneddescriptorontopofthescreen.TheSecurityButtonbecomesyellow(showingthatazoneisopen).
Walk Test
1 FromtheInstallerToolbox,selectwalktest.
2 OpenandclosetheDW10.ThisactioncausestheControlPaneltodisplaythesignalstrengthoftheDW10.
3 ExittheInstallerToo l b ox.
Installing and Mounting
For internal switch usage, do the following:
1 Mountthesensoronthedoorframeandthemagnetonthedoor.Ifthesensorisusedondoubledoors,mountthe
sensorontheleastuseddoorandthemagnetonthemostuseddoor.
TIP: Ifpossible,locatesensorswithin100ft.(30m)oftheControlPanel.Whileatransmittermayhavearangeof350
ft.(106m)ormoreoutintheopen,theenvironmentattheinstallationsitecanhaveasignificanteffecton
transmitterrange.Sometimesachangeinsensororientationcanhe
lpovercomeadversewirelessconditions.
2 Makesurethealignmentarrowonthemagnetpointstothealignmentmarkonthesensor(seethefigureabove).
3 Placesensorsatleast4.7in.(12cm)abovethefloortoavoiddamagingthem.
4 Avoidmountingsensorsinareaswheretheywillbeexposedtomoistureorwherethesensoroperating
temperaturerangeof32to120°F(0to49°C)willbeexceeded.
5 Usespacers(notincluded)tokeepsensorsandmagnetsawayfrommetalormetallicsurfacessuchasfoil
wallpaper.
FCCID:WDQDW10345
IndustryCanadaID:7794ADW10345
THIN DOOR/WINDOW CONTACT

Summary of content (2 pages)