Connect the Backup Battery
After connecting or wiring the DC power supply on the panel, use these steps to connect the backup battery.
To connect the backup battery:
1. Ensure the backup battery is properly seated in the GC3 chassis. The battery’s label should be facing up and
the battery’s connector wire should be on the left with the wire running in the empty space between the battery
compartment and Cellular Radio Module’s compartment
2. Insert the wired battery pin into the PCB battery connector. The connector is located directly behind the DC power
adapter barrel jack.
GC3 Panel—Backup Battery Connector
Important: The GC3 Panel will not recognize the
backup battery connection until you plug the AC power
supply into the wall outlet.
Warning!!: Do NOT plug the power supply into the
outlet at this time. Always complete all system wiring
and then secure the backplate to the GC3 Panel before
connecting its power supply to the outlet.
Hang the GC3 Panel
To hang the GC3 Panel on the mounting plate:
1. Ensure all installed wiring is securely fastened.
2. Ensure the connector to the Piezo Sounder is secure.
GC3 Panel—Interal Siren/Speaker Connector
3. Ensure the connector to the internal siren/speaker is
secure.
4. Place the backplate over the lower lip on the back of
the chassis and fl ip the GC3 Panel upwards.
5. Push the GC3 Panel over the mounting bracket until it
clicks into place.
Note: Continue with the next step in the section
that follows titled, “Install the Retaining Wall Bracket
and Connect the AC Power Supply.”
Ethernet Module Installation (Optional)
An Ethernet module can be added to the GC3 Panel to
allow a hardware network connection to the system.
Note: Only a single broadband is available on the
GC3 panel at any time. If a hardwired connection
is active on the GC3 the WiFi connection will be
disabled.