Q35: Broadband network failure reports
Confi gures the system to tranmit a trouble report to the
Central Station when the system detects a broadband
network connection(WiFi or Ethernet).
Choose one of these options:
»
† Enabled: Turns the reporting feature ON. The
GC3 Panel will transmit a trouble report to the
Central Station after a broadband network failure.
»
Disabled: Turns the reporting feature OFF. The
GC3 Panel will not transmit a trouble report to the
Central Station after a broadband network failure.
Q36: Periodic test, in days (0-255)
Confi gures the system to automatically transmit periodic
test reports about the GC3 Panel’s connections to the
Central Station at the recurring interval you specify here.
Choose one of these options:
»
0 Days: Turns the feature OFF. The system does not
transmit periodic test reports to the Central Station.
»
1-255 Days: Turns the feature ON. The system
transmits periodic test reports to the Central Station
at recurring intervals using the number of days
specifi ed here.
»
† 30 Days: Turns the feature ON. The system
transmits periodic test reports to the Central Station
once every 30 days.
Q37: Alarm cancel time, in minutes (5-255)
Confi gures the system to transmit a cancellation report to
the Central Station whenever an alarm is canceled by a
user within the amount of time specifi ed here. To learn how
to change the setting for the alarm information that displays
on the touchscreen, see “Q38: Alarm cancel display” below.
»
† ‡ 5 Minutes: For compliance with ANSI/SIA CP-
01-2010, the minimum required setting is 5 minutes.
This can be extended to a greater number of
minutes without aff ecting compliance.
»
6-254 Minutes: Enter a value between 6 and 254
minutes.
»
255: To transmit a cancellation report anytime the
system is disarmed after an alarm, enter 255.
Q38: Alarm cancel display
Confi gures the system to display an alert message letting
the user know that an alarm cancellation report was sent to
the Central Station. The message is displayed if the alarm
is canceled within the number of minutes specifi ed in “Q37:
Alarm cancel time, in minutes (5-255).”
Choose one of these options:
»
† ‡ Enabled: Turns the feature ON. This displays
an alert message notifying the user that an alarm
cancellation report was sent to the Central Station.
For compliance with ANSI/SIA CP- 01-2010, the
default setting for this feature is enabled.
»
Disabled: Turns the feature OFF. The system will not
display an alert message when a cancellation report
is sent to the Central Station.
Q39: Alarm abort window transmission delay
Confi gures the amount of time the system will wait to
initiate the digital transmission when an alarm condition is
triggered. This setting specifi es the number of seconds the
user has to manually abort the alarm, in the event of a false
alarm.
NOTE: The transmission delay can be increased
to 45 seconds without aff ecting ANSI/SIA CP-01
compliance only if the combination of Q39 and “Q5:
Entry delay 1, in seconds (30-240)” in “Q6: Entry
delay 2, in seconds (30- 240)” does not exceed one
(1) minute.
Choose one of these options:
»
15 seconds: The system waits 15 seconds to initiate
the dialer.
»
† ‡ 30 seconds: For compliance with ANSI/SIA CP-
01-2010, the default minimum setting is 30 seconds.
This setting can be increased to 45 seconds without
aff ecting compliance only if the combination of this
setting.
»
45 seconds: The system waits 45 seconds to initiate
the dialer.
Q40: Burglary bell cutoff time
Defi nes the amount of time the system sounds the burglary
alarm after the alarm is activated. After the time set here
expires, the alarm siren shuts OFF.
NOTE: This setting only aff ects the GC3 Panel
alarm. It does not aff ect any auxiliary alarms that
may be installed. Typically, auxiliary alarms are set
to sound for an unlimited amount of time.
Choose one of these options:
»
† 4 Minutes: The alarm siren shuts OFF after 4
minutes.
»
8 Minutes: The alarm siren shuts OFF after 8
minutes.
»
12 Minutes: The alarm siren shuts OFF after 12
minutes.
»
16 Minutes: The alarm siren shuts OFF after 16
minutes.
»
Unlimited Time: The alarm siren must be shut OFF
manually.
Q41: Fire bell cutoff time
Specifi es the amount of time a Carbon Monoxide Detector
or Smoke/Heat/Freeze Alarm should sound after the alarm
is activated. After the time set here expires, the alarm siren
shuts OFF.
NOTE: This setting only aff ects the GC3 Panel
alarm. It does not aff ect any auxiliary alarms that