Advanced Manual

Copyright © 2019 Nortek Security & Control LLC
64
Q62: Smart test reports
Confi gures the system to transmit smart test reports to
the Central Station. A smart test report is designed to
reduce incoming network traffi c for the Central Station.
When enabled in combination with “Q36: Periodic test, in
days (0-255),” all non-test reports occurring during normal
operations will restart the periodic test report timer (for
example, alarm, restore, trouble, etc.). Periodic test reports
are only sent when the GC3 Panel has not reported in any
way to the Central Station.
Choose one of these options:
»
Enabled: The system transmits a report to the
Central Station.
»
† Disabled: The system does not transmit a report to
the Central Station.
Q63: RF jam causes trouble
Confi gures the system to activate a trouble condition
when the GC3 Panel’s wireless receiver detects that one
of the system’s RF transmitters is causing an RF jam. For
this setting to go into aff ect, you must also enable “Q49:
Trouble reports to CS” on the previous page.
Choose one of these options:
»
Enabled: The system detects RF jamming.
»
† Disabled: The system does not detect RF
jamming.
Q64: System tamper causes trouble
Confi gures the system to activate a trouble condition if one
of the GC3 Panel’s tamper switches (wall tamper switch or
cell radio tamper switch) is triggered while the system is
disarmed. The system will also activate an alarm condition
if a tamper switch is triggered while the system is armed.
You have these options:
»
† Enabled: The system activates a trouble condition.
»
Disabled: The system does not activate a trouble
condition.
Q65: Auto unbypass for manual bypass
Manually bypassed sensors can have their bypass
automatically removed at disarming or have their bypasses
remain in place.
You have these options:
»
† Enabled: Turns the feature ON. The system
automatically removes bypasses from manually
bypassed sensors when the system is disarmed.
»
Disabled: Turns the feature OFF. Manually bypassed
sensors will remain bypassed when the system is
disarmed.
Q66: Force bypass reports
Confi gures the system to transmit a report to the Central
Station when a user force-bypasses a sensor while the
system is armed.
You have these options:
»
Enabled: The system transmits a report to the
Central Station.
»
† Disabled: The system does not transmit a report to
the Central Station.
NOTE: Forced bypassed sensors are always
recorded in the event log, regardless of the setting
of this programming question.
Q67: Event log
Confi gures the system to defi ne the types of system events
that are recorded in the system’s History.
You have these options:
»
Disabled : Does not record events.
»
All Events Except Open/Close/Bypass: Records
all events, except sensor opening, closing, and
bypassing.
»
All Events Except Open/Close: Records all events,
except sensor opening and closing.
»
All Events: Records all events.
Q68: Allow backlight always on (demo mode)
Confi gures the system to always leave the touchscreen’s
backlight on. This is useful when users want to demonstrate
panel features, without the system backlight timing out.
Important: Leaving the backlight ON for extended
periods of time may result in image retention. To
avoid this, it is recommended that you only enable
this feature when the panel is intended for use as a
demonstration system.
Choose one of these options:
»
Enabled: The backlight for the touchscreen is
always ON.
»
† Disabled: The backlight for the touchscreen dims
automatically after 60 seconds of inactivity.
Q69: Smart Areas
Confi gures “Smart Areas” (partitioning) feature allowing
the sytem to be divided into four separate areas. Once
enabled, zones, keyfobs, keypads, and users can be
assigned to Smart Areas allowing individual control of each
area.
Choose one of these options:
»
Enabled: Smart Areas button will be displayed on
GC3 Panel and all SP1 keypads. Zones, Keyfobs,
Keypads can be assigned to a single Smart Area.
Users can be assigned and control assigned Smart
Areas. Smart Areas Settings will allow naming of all
four areas.
»
† Disabled: Smart Areas button will not be
displayed on the home screen of the GC3 and
SP1s. Smart Areas Settings will only display the
main system.