Features to Limit False Alarms
For compliance with ANSI/SIA CP-01-2010: Control Panel Standard - Features for False Alarm Reduction, the installer
can set a variety of diff erent options designed to limit occurrences of a False Alarm.
ANSI/SIA CP-01-2010 Features to Limit False Alarms
ANSI/SIA CP-01-2010 2GIG System Feature Installation & Programming Guide
4.2.2.1 Exit Time Exit Delay
“Q4: Exit delay, in seconds (45-120)”
“Q16: Allow quick exit”
4.2.2.2 Progress Annunciation Exit Delay Announcement “Q4: Exit delay, in seconds (45-120)”
4.2.2.3 Exit Time Restart Exit Delay Restart “Q15: Exit delay restart”
4.2.2.4 Exit Error Exit Error See the GC3 User Guide
4.2.2.5 Unvacated Premises Auto Stay “Q14: Auto stay”
4.2.3.1 Entry Delay Entry Delay
“Q5: Entry delay 1, in seconds (30-240)”
“Q6: Entry delay 2, in seconds (30-240)”
4.3.2.2 Progress Annunciation Entry Delay Announcement
“Q1: Enter installer code (4 digits)”
“Q1: Enter installer code (4 digits)”
4.3.2.3 Disarm Disarming Features See the GC3 User Guide
4.2.4.1 Control Buttons Keyfob/Remote Arming Mode on System Not Ready.
“Q20: Keyfob/remote arming mode on system not
ready”
4.2.4.2 Manual Alarms Emergency Alarm Features See the GC3 User Guide
4.2.4.3 System Acknowledgment
Alert Keyfob Disarming After Alarm
Keyfob Arm/Disarm Confi rmation
“Q18: Alert on disarm with keyfob after alarm”
“Q18: Alert on disarm with keyfob after alarm”
4.2.4.4 Remote Arming Key Fob Arming “Q18: Alert on disarm with keyfob after alarm”
4.3.4.5 Remote Disarming Key Fob Arming “Q19: Keyfob arm/disarm confi rmation”
4.2.5.1 Abort Window Abort Window Dialer Delay “Q39: Alarm abort window transmission delay”
4.2.5.1.1 Disarm Abort Window Dialer Delay “Q36: Periodic test, in days (0-255)”
4.2.5.1.2 Abort Abort Window Dialer Delay “Q36: Periodic test, in days (0-255)”
4.2.5.2 Alarm Transmission Abort Window Dialer Delay “Q39: Alarm abort window transmission delay”
4.2.5.3 Disarm Disarm See the GC3 User Guide
4.2.5.4 Cancel Window Alarm Cancel Time, Alarm Cancel Display “Q37: Alarm cancel time, in minutes (5-255)”
4.2.6.1 Use of Duress Feature User Duress Report See the GC3 User Guide
4.2.6.2 Duress Code Duress Code See the GC3 User Guide
4.2.7 Initiation of Manual Alarms Panic, Fire, or Emergency Alarm See the GC3 User Guide
4.3. Cross Zoning Cross Sensor Zones, Cross Sensor Timeout
“Q26: Cross sensor zones 99-100”
“Q27: Cross sensor timeout, in seconds (10-120)”
4.3.2 Swinger Shutdown Swinger Shutdown Count (1-6)
“Q25: Swinger shutdown count (1-6)”
“Q61: Alarm restore reports to CS”
4.3.3 Fire Alarms Fire & Carbon Monoxide Protection Sensor Type — (24) Silent Burglary”
4.6.3 System Test
Console Test
Sensors Test
“Testing the Installation”