Advanced Manual

Copyright © 2019 Nortek Security & Control LLC
87
5. At the Smart Home Settings menu, tap Advanced
Settings.
Smart Home Settings—Advanced Settings
6. At the Advanced Settings menu, tap Controller
Learn.
Advanced Settings—Controller Learn
The GC3 Panel displays a “Learning Z-Wave Controller”
message and waits for a signal from the primary controller.
The synchronization takes time, depending upon the
number of Z- Wave devices in the network.
Note: If a new Z-Wave device is added to the
network, the secondary controller must be re-
learned into the network.
Testing the Installation
Disable the Piezo Sounder
To disable the system’s sounder, navigate to the Installer
Toolbox. Then tap Disable Sounder. At the Sounder
Disabled message, tap OK. The sounder is disabled for 30
minutes (or until you tap the Re- enable Sounder button).
Perform a Walk Test
After installing the system, sensors, and peripherals,
perform a walk test to ensure proper console operations
and to test wireless reception and signal strength. To open
the Walk Test menu, navigate to the Installer Toolbox.
Then tap Walk Test.
»
To test wireless reception and signal strength,
tap Sensors Test. Then walk to and trigger each
sensor.
Walk Test—Sensors Test Screen
»
After you have tested all sensors, press .
»
To test the console operations, tap Console Test.
Then tap each button and respond Yes or No to
each question.
Walk Test—Console Test Screen
»
After you have tested all console functions,
press
y
.
Note: For compliance with ANSI/SIA CP-01-2010,
when you tap Sensors Test or Console Test, the
system sends a Walk Test Started message to the
Central Station. When you exit the test, the system
sends a Walk Test Terminated message to the
Central Station.