CONFIGURATION
The LBR30Z-1 supports the Confi guration command. The LBR30Z-1 can be
confi gured to operate slightly differently than how it works when you fi rst install
it. Using the Confi guration command you can confi gure the following:
Parameter 1: Dim Level Memory
By default, the LBR30Z-1 bulb will go to full brightness when turned on. To have
the bulb turn on to the last dim level setting, set Parameter 1 to 1.
Parameter Length Valid Values Confi guration Option
1
1 Byte
0
Bulb will be full brightness when turned on (default)
1 Bulb will turn on to the last dim level setting
Parameter 9: Dim / Bright Step Level
When the brightness is adjusted by the controller/gateway, how much the bulb
brightness will change is set by the programmed dimming step level.
Parameter Length Valid Values Confi guration Option
9
1 Byte 1 - 99
Default = 1
The step level is small when the value is low
The step level is large when the value is high
Parameter 10: Dim / Bright Speed
When the brightness is adjusted by the controller/gateway, how fast the bulb
brightness will change is set by the programmed dimming step speed.
Parameter Length Valid Values Confi guration Option
10
1 Byte 1 - 10
Default = 3
The step speed is fast when the value is low
The step speed is slow when the value is high
Example: If Parameter 9 is set to the default value of 1, setting Parameter 10
from 1 to 10 will equal the number of seconds it takes to dim down the bulb
when the bulb is turned off, i.e. 1 equals 1 second for the bulb to dim down and
turn off, 10 equals 10 seconds for the bulb to dim down and turn OFF.
Z-Wave Plus Features
The LBR30Z-1 contains a Z-Wave 500 Series Module that supports Z-Wave
Plus features. A Z-Wave certifi ed portable or stationary controller can
communicate with the Z-Wave 500 Series Module.
Depending on the capability of the controller or gateway software, the following
operations can be performed with the Smart LED Light Bulb. Refer to the
controller or gateway manual for details.
Turn the bulb ON and OFF.
Dim the bulb.
Add or Remove the Smart LED Light Bulb.
Assign the Smart LED Light Bulb to a specific Group/Scene and/or to
include the bulb as part of ALL ON or ALL OFF system commands.
Over-the-air firmware update by the gateway or static controller.
Lifeline function which automatically notifies the associated modules and
the network that a manually reset device is no longer in the network, thus,
the corresponding association becomes invalid.
INTEROPERABILITY WITH Z-WAVE DEVICES
A Z-Wave network can integrate devices of various classes of products, and
these devices can be made by different manufacturers. The GoControl Smart
LED Light Bulb has Z-Wave certifi cation which guarantees interoperability.
ASSOCIATION
The LBR30Z-1 supports one Group with fi ve Nodes for lifeline communication.
Group 1 must be assigned the Node ID of the controller to which unsolicited
notifi cations from the LBR30Z-1 will be sent. The Z-Wave controller should
set this association automatically after inclusion. You can associate up to fi ve
Z-Wave devices to Group 1. Lifeline association only supports the “manual
reset” event.
For instructions on how to “set lifeline association” please refer to your wireless
controller instructions.
SPECIFICATIONS
Power Supply 120 VAC, 60 Hz
Brightness 650 lumens (Equivalent to 65 Watt incandescent light
bulb)
Power Consumption 7.5 Watts
Color Temperature 5000K
Bulb Lifetime 25,000 hour (equivalent 22.8 years based on 3 hours/
day)
Radio Frequency 908.4 MHz / 916 MHz
Wireless Range Up to 130 feet line of sight between the Z-Wave
Controller and/or the closest Z-Wave Repeater
Normal Operating Temp 77°F (25°C)
Repeater Ye s
Z-Wave
®
and Z-Wave Plus
®
are registered trademarks of Sigma Designs
and its subsidiaries in the United States and other countries.
REGULATORY INFORMATION
The LBR30Z-1 is certifi ed to comply with applicable FCC and IC rules and regulations governing RF and EMI
emissions.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any interference received, including interference
received that may cause undesired operation.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician to help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment
IC Notice
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Le présent appareil est conforme
aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This device complies with the Industry Canada license exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
WARRANTY
This Nortek Security & Control product is warranted against defects in material and workmanship for twenty four (24)
months based on three (3) hours of use per day. This warranty extends only to wholesale customers who buy
direct from Nortek Security & Control or through Nortek Security & Control’s normal distribution channels. Nortek
Security & Control does not warrant this product to consumers. Consumers should inquire from their selling dealer as
to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Nortek Security
& Control for consequential damages arising out of or in connection with use or performance of this product
or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation,
or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for
tness, are valid only until Warranty Expiration Date as labeled on the product. This Nortek Security & Control LLC
Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a
Return Product Authorization Number (RPA#). Contact Nortek Security & Control Returns at 1-855-546-3279 for an
RPA# and other important details.
IMPORTANT !!!
Radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling.
However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices.
As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that
occur on or near their operating frequencies, regardless of code settings.
Changes or modifications to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer,
and these facts should be communicated to the ultimate users.
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,LBR30Z-1; P/N: 10006193 X8; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500” x 11.000”; TOL ± .125”; SCALE: 1-1; FOLDING: 4-FOLD ALTERNATE; SIDE 2 OF 2