The 2N TELEKOMUNIKACE a.s. joint-stock company is a Czech manufacturer and supplier of telecommunications equipment. The product family developed by 2N TELEKOMUNIKACE a.s. includes GSM gateways, private branch exchanges (PBX), and door and lift communicators. 2N TELEKOMUNIKACE a.s. has been ranked among the Czech top companies for years and represented a symbol of stability and prosperity on the telecommunications market for almost two decades.
Table of Contents 1. Product Overview............................................................... 7 1.1 Product Description ....................................................................................................... 8 Basic Features.................................................................................................................. 8 Advantages of 2N® EasyGate use ................................................................................... 8 Safety Precautions ...........
FXS Routing Parameters ............................................................................................... 33 FAX/DATA routing parametres....................................................................................... 36 SMS Sending Input Parameters ..................................................................................... 36 GSM & SIM Parameters ................................................................................................. 37 Service Parameters .............
6.1 Regulations and directives.......................................................................................... 62 6.2 List of Figures ............................................................................................................... 63 6.3 Troubleshooting ........................................................................................................... 64 6.4 List of Abbreviations .........................................................................................
1 1. Product Overview In this section, we introduce the2N® EasyGate product, outline its application options and highlight the advantages following from its use. This chapter also includes safety instructions. Here is what you can find in this section: Product Description Associated Products Manual changes description Abbreviations, Terms and Pictograms Used.
Product Description 1.1 1.1 Product Description Basic Features The primary purpose of EasyGate is to transmit voice between a GSM network and an attached FXO-interface terminal (PBX, telephone, answering machine, etc.). You can establish data connections (GPRS, CSD) and send/receive SMS using EasyGate in combination with a PC and appropriate software. You can send an SMS to a pre-programmed number using the SMS sending input. Analogue fax transmition on some models.
Product Description 1.1 Safety Precautions Do not switch on 2N® EasyGate in the vicinity of medical apparatuses to avoid interference. The minimum distance of the antenna and pacemakers should be 0.5m. Do not switch on 2N® EasyGate aboard of a plane. Do not switch on 2N® EasyGate near petrol stations, chemical facilities or sites where explosives are used. Any mobile telephone use prohibition based on RF energy radiation applies to 2N® EasyGate too.
Changes 1.2 1.2 Changes Manual Version Amendments to Earlier Versions 1.00 The User Manual applies to EasyGate FW Version 1.00D. New parameter for dial tone setting. 1.01 LED indications updated. The User Manual applies to EasyGate FW Version 1.00E 1.02 Default setting for dial tone is continuous tone now. The User Manual applies to EasyGate FW Version 1.00F New function: tariff metering with 16 or 12 kHz pulses. 1.03 New function: call connect and disconnect signaling by 16 or 12 kHz pulses.
Terms and Symbols Used 1.3 1.3 Terms and Symbols Used Manual Symbols Safety Always abide by this information to prevent persons from injury. Warning Always abide by this information to prevent damage to the device. Caution Important information for system functionality. Tip Useful information for quick and efficient functionality. Note Routines or advice for efficient use of the device.
2 2. Description and Installation This section describes the 2N® EasyGate product and its installation.
Description 2.1 2.1 Description 2N® EasyGate consites of GSM gateway in white plastic cover, removable antenna and cables for connecting to phone set and PC 2N® EasyGate ’s status is indicated by LED diodes on its front side. All possible states are described in the following figure. Figure 2.
Description 2.1 Telephone Line Tones – Operational Tones The GSM gateway sends tones to the telephone line to indicate the line status. The tone frequency is 425 Hz. Dial tone continuous or morse A EasyGate is registered to GSM network and ready to receive dialing. Ringing tone The called subscriber's telephone is ringing. The GSM network transmits this tone. Busy tone The busy tone is transmitted in any of the following cases: The SIM card has not been installed.
Description 2.1 PUK tone Enter the PUK code. This tone is transmitted upon repeated wrong PIN entering attempts. SIM card is blocked. Telephone Line Tones – Programming Mode Tones confirming/refusing the values entered are transmitted during telephone line based programming. Each tone has a different melody. Confirmation Confirms that the service password or parameter number entered is correct and has been accepted.
Before You Start 2.2 2.
Before You Start 2.2 It is impossible to operate EasyGate on sites exposed to direct solar radiation or near heat sources. EasyGate is designed for indoor use. It may not be exposed to rain, flowing water, condensed moisture, fog, etc. EasyGate may not be exposed to aggressive gas, acid vapours, solvents, etc.
Mounting 2.3 2.3 Mounting External Antenna Connection Screw the antenna enclosed into the SMA antenna connector. Caution Tighten the antenna connector gently with your hand – never use wrenches! Note The antenna enclosed has a sufficient gain for trouble-free operation in normal conditions. If the UMTS signal is poor or you want to place your antenna separately from EasyGate , you can use an antenna with an SMAconnector terminated cable. The antenna should be mounted vertically.
Mounting 2.3 Wall mounting 2N® EasyGate is equipped with two hangings on the back side for wall mounting. For drilling holes to the wall could be used drill pattern in QuickStart. Figure 2.4 Zavěšení 2N® EasyGate na zeď Power Supply Connection 2N® EasyGate is fed with 10-16V DC. Where a source other than the included power supply adapter is used, the voltage range and polarity shown on the EasyGate power supply connector have to be maintained.
Telephone line connection 2.4 2.4 Telephone line connection PBX Connection Connect 2N® EasyGate to a free CO line of your PBX. Configure your PBX in such a manner that GSM outgoing calls are routed to 2N® EasyGate. Tip 2N® EasyGate is equipped with the FSK-based CLIP function. If your PBX is able to process the caller’s ID, you are advised to enable this function.
SMS Sending Input Connection 2.5 2.5 SMS Sending Input Connection You have got a special connector for easy connection to EasyGate. The connector is equipped with screwing clamps to connect wires leading to a switching contact (device to be monitored). The other connector end can be connected to the respective EasyGate panel connector. The input is designed for the switching contact connected between the input pins. The input is activated by contact closing (pin interconnection).
3 3. Configuration ® 2N EasyGate This section describes configuration of the product 2N® EasyGate. Here is what you can find in this section: PC Connection to 2N® EasyGate EasyGate Parameter Programming Table of Parameters.
2N® EasyGate parameters configuration 3.1 3.1 2N® EasyGate parameters configuration PC Connection You have got a serial cable for PC connection. It is a modem cable where all of the 9 pins are 1:1 interconnected – in case you wanted to use another, longer cable. Caution Make sure that a longer cable works properly to avoid errors at high transmission rates. EasyGate Parameter Programming All EasyGate parameters have such default values that meet most users’ demands and need not be changed.
2N® EasyGate parameters configuration 3.1 To cancel any programming step in the programming mode, press a . Having done so, you can hear the refusal tone and can enter a new parameter number. Parameters are saved when the saving tone is transmitted. Hang up to quit programming.
2N® EasyGate parameters configuration 3.1 Basic Programming Instructions 1. Run the PCManager and select the language for displaying texts on the righthand side. 2. Click on the CD-ROM icon for data handling on the left-hand side. 3. Load data from EasyGate – if EasyGate is not in its special programming mode, you are invited to switch EasyGate off and on again. 4. Click on the programming table icon on the left-hand side. 5. The parameters are arranged according to their functions in the tables.
2N® EasyGate parameters configuration 3.1 Monitoring Monitoring is active when EasyGate is in operation and registered to the GSM network. If EasyGate is not registered to GSM, the COM is locked and no monitoring can be made.
2N® EasyGate parameters configuration 3.1 The hardware version setting must conform to hardware version of connected gateway. There are two hardware versions of EasyGate: A or B. Version A is the older one, it is not produced currently, this setting is only for reverse compatibility. Version B is equipped with more memory and offers more functionality. You can recognize version of your EasyGate after loading parameters from EasyGate in table Service. For hardware version A can be used only formware 1.
Table of Parameters 3.2 3.2 Table of Parameters All programmable parameters are listed in this section. Each parameter is accompanied with the unit used, function number (if available) for programming via a telephone line, description of EasyGate's behavior, setting options, setting step and default (initialization) value. Telephone Line Parameters Dialing parameters Type of dialing Function No.: - Select the dialing type to be received by EasyGate from the PBX or telephone set.
Table of Parameters 3.2 Signaling Line reversal indication for call in progress Function No.: - Select call in progress signaling by telephone line polarity reversal. There is voltage of reversed polarity on the telephone line during the whole call. Setting options: YES/NO Default setting: NO Tariff pulse when call starts/ends Function No.: - Signaling of call start or end by tariff pulse. Setting options: None -EasyGate doesn't send tariff pulse as signaling of call start/end.
Table of Parameters Dial tone - cadence Function No.: 3.2 - This tone is generated after Off-Hook in case EasyGate is ready to accept dialing. Setting options: Continuous -EasyGate generate continuous dial tone Morse A -EasyGate generate dial tone with 320/320/640/640 ms cadence Default setting: Continuous Busy tone – Double frequency tone[Hz] Function No.: - Set for double frequency tones Setting options: YES/NO Default setting: NO Busy tone – frequency [Hz] Function No.
Table of Parameters 3.2 Volumes Transmission volume Function No.: 10 Volume setting for GSM transmission with a 4 dB step. Setting options: 1-5 Setting step: 1 Default setting: 3 = medium volume level Reception volume Function No.: 11 Volume setting for GSM reception with a 4 dB step. Setting options: 1-5 Setting step: 1 Default setting: 3 = medium volume level Ringing signal settings Ringing signal – frequency [Hz] Function No.: - Ringing signal frequency setting.
Table of Parameters CLI transmitting Function No.: 3.2 19 Set this item to enable/disable identification of a telephone line calling from a GSM network. The function can be enabled if you have a device on your telephone line that is capable of receiving FSK according to ETSI standards. Setting options: Disable -EasyGate does not transmit the CLI. FSK during ringing -EasyGate transmits the FSKbased CLI according to the ETSI EN 300 659 standard (transmission during ringing). Tbd.
Table of Parameters 3.2 Every table line includes a prefix (of variable length) plus parameters that define EasyGate's behavior in case the beginning of the dialed number matches this prefix. The table can contain up to 20 different prefixes. There may be exceptions to the rule - a number may start with the same digits but has to be served in a different way. Any table line that starts with the same prefix followed by one or more digits is considered an exception of the line with shorter prefix.
Table of Parameters Prefix Function No.: 3.2 - A prefix identifying the call type (GSM, trunk call, free call, etc.). "Other numbers" line is used for calls with prefixes that are not included in the table. Setting options: 0-14 characters (0-9,*,#) Default setting: blank Call enable Function No.: - This parameter allows/bars calls with prefixes included on the same line. Setting options: YES/NO Default setting: YES Number length Function No.
Table of Parameters Extra tariff Function No.: 3.2 - Pseudo tariff metering setting (tariff is based on call duration). The Extra tariff parameter defines transmitting of fixed quantity of tariff pulses after call start. This parameter sets minimal call cost. Setting options: 0-255 Setting step: 1 Default setting: 0 Tariff [s] Function No.: - Pseudo tariff metering setting (tariff is based on call duration). The Tariff parameter sets the call cost according to call duration.
Table of Parameters SMS text Function No.: 3.2 - The SMS text to be sent to the preset telephone number. If the SMS text is blank, an empty SMS is sent. Setting options: 0-40 characters Default setting: blank Send if activated longer than [ms] Function No.: - Set the SMS activation time necessary for SMS sending. This parameter prevents SMS sending in the event of short-time activation. If a "0" is selected, SMS is sent immediately upon the input activation.
Table of Parameters Roaming enable/disable Function No.: 3.2 42 You can make EasyGate work even if it is registered to a foreign GSM network. Setting options: -Disable -The GSM module logs out of a foreign network and attempts to register again in within 5 minutes. -Enable -EasyGate works in any GSM network. Default setting: Disable Incoming calls enable Function No.: 43 With this parameter you can reject all incoming calls.
Table of Parameters Minimal credit Function No.: 3.2 - Set minimal credit value to send warning SMS "LOW CREDIT". If credit is lower then given value, warning SMS is send after every credit check, until you recharge your SIM card. Setting options: 0-999 Step: 1 Default setting: 0 Credit value position in received SMS Function No.: - If there are more numbers except credit value in text answer (e.g.
Table of Parameters COM enable Function No.: 3.2 50 With this parameter you can enable/disable the serial interface function. You can disable communication in the operating mode, maintaining the special programming mode after power up. Setting options: YES/NO Default setting: YES Time period for GGMC SMS [h] Function No.: - Time interval for GGMC SMS sending. GGMC = GSM Gateway Monitoring Centre. The "0" setting means that the function is disabled.
Table of Parameters Global initialization Function No.: 3.2 99 Initialization of all EasyGate parameters including the PIN and service password. Security Parameters PIN - value Function No.: 40 Fill in the PIN value for automatic PIN entering upon EasyGate power up. It is applied only if the SIM card is PIN secured. If the given PIN fails to match the SIM, it is deleted automatically. If entered via a telephone line upon EasyGate start, the PIN is stored automatically.
4 4. Function and Use This section describes the basic and extending functions of the product 2N® EasyGate . Here is what you can find in this section: Voice function FAX and Data function SMS Sending Input COM – Serial Interface SIM Card PIN protection.
Voice function 4.1 4.1 Voice function Outgoing and incoming call establishing procedures for an analog telephone are described for illustration. The procedures are the same for the EasyGate-PBX connection, just remember to program call routing to EasyGate properly. Check EasyGate’s function by connecting a telephone before.
Voice function 4.1 dialing during the BabyCall timeout cancels this function and a standard outgoing call can be made. Tariff pulses 16 or 12 kHz EasyGate has tariff pulse transmitter. You can use tariff pulses for outgoing call pricing. EasyGate offer pseudotariff only – tariff metering doesn’t correspond to real price of call, tariff pulses are transmitted according to programmed parameters and call duration.
Voice function 4.1 Call forwarding For forwarding activation you must specify the calls will be forwarded to. You may specify , if you want to forward specified call type only. You may specify in seconds for forwarding if no answer too. Description of field codes: Voice: Data: Fax: Call forwarding unconditional If activated, incoming calls will be always forwarded to the configured telephone number.
Voice function 4.1 Call forwarding if no answer If activated, incoming calls will be forwarded to the configured telephone number if incoming call isn’t answered during specified timeout. Default timeout is 20 seconds.
Voice function 4.1 Call waiting If the call waiting is activated the incoming call isn’t refused if there is call in progress on EasyGate. If there is the other incoming call during connected call it will be indicated by tone. See 0. for multiple calls management. Activation: Deactivation: Status check: Call hold Check if your network supports the service before you use it. This service relates to Call waiting described in 5.7.
FAX and Data function 4.2 4.2 FAX and Data function Only EasyGate with fax converter supports fax and data functions. Sending fax message or modem connection to and from GSM GSM fax and Data connection EasyGate with fax converter has ability to send and receive GSM fax messages using analogue fax Group 3 connected to telephone line FXS. The fax communication service must be registered with your GSM operator. It is possible to establish data connection using analog modem connected to FXS line.
FAX and Data function 4.2 DTMF codes for data receive: *9800# Reset of all following settings for data receive *9801# The next call are data, this setting is suspended after receiving call or by command *9800# *9802# Data routed to FXS, inactivate *9800# or device reset + *9803# Data routed to COM, inactivate *9800# or device reset + Commands marked + are used to set parameters, which can be set permanently in configuration program (PCManager).
SMS Sending Input 4.3 4.3 SMS Sending Input This universal input is intended especially for reporting alarm or error statuses of any equipment provided with the appropriate contact (a relay contact, e.g.). By activating this input (electric input pin interconnection) you send one SMS to one pre-programmed telephone number. Caution Do not use in life-supporting or property-protection applications because of the character of SMS service and EasyGate.
COM – Serial Interface 4.4 4.4 COM – Serial Interface The complete serial interface RS-232C on a 9-pin connector is identical with any external modem. The transmission rate ranges from 1200 to 115200 bps (EasyGate supports autobauding, i.e. responds to an AT command at a rate identical with the AT command transmission rate, and retains set on this rate). The transmission setup must be 8 bits, no parity and one STOP bit (8N1).
COM – Serial Interface 4.4 CSD or High-Speed GPRS Data Connection to Internet To connect to the Internet, install the faxmodem driver from the EasyGate CD-ROM first. Another possibility is to use the GSM provider’s installation wizard in case it supports the SIEMENS GSM module installed in EasyGate (SIEMENS MC39i, MC55, MC56 or MC55i). GPRS/faxmodem driver can be found on installation CD. The path to the driver is \\data\EasyGate\Modem driver\. Driver’s filename is mdm2n_vx.x.inf where x.
COM – Serial Interface 4.4 Outgoing and incoming calls can be made during GPRS connection. The GPRS connection remains active during the whole call but no data can be transmitted (EasyGate is a GPRS terminal of class B). Once the call is terminated, data transmission is recovered immediately. List of Supported AT Commands There are original files related to SIEMENS GSM modules in the PDF format on the EasyGate CD-ROM.
SIM Card PIN protection 4.5 4.5 SIM Card PIN protection If a SIM card is PIN-protected and the PIN is not programmed in EasyGate, GSM LED indicates the state and the PIN tone is transmitted on telephone line. PIN Entering by PCManager Like other parameters, the PIN code can be entered using a PC programming tool. The PIN will be entered automatically upon next EasyGate power up. PIN Entering via Telephone Line To enter the PIN via a telephone line using the DTMF: 1.
5 5. Technical parameters This section describes the technical parameters of the product 2N® EasyGate .
Technical Parameters 5.1 5.1 Technical Parameters GSM MC39i EGSM 900 / GSM 1800 MC55 EGSM 900 / GSM 1800 / GSM 1900 GSM module, GSM bandwidth MC56 EGSM 850 / GSM 1800 / GSM 1900 MC55i EGSM 850/ EGSM 900/ GSM 1800/ GSM 1900 Transmission power 2 W EGSM 850 / 900 MHz, 1W GSM 1800 / 1900 MHz Receiver sensitivity -105 dBm Audio DATA Fax Antenna SIM card HR+FR+EFR Half rate+Full rate+Enhanced full rate Echo cancellation, Echo suppression GPRS Class 10, 4+2 max. 85.6 kbps downlink CSD max. 14.
Technical Parameters Loop voltage 48 V DC Loop current max. 40 mA Loop resistance max. 800 Ω Tone frequency adjustable, default 425 Hz Dialing type tone (DTMF) and pulse Ringing voltage 42 Vrms 50/25 Hz Calling line identification CLI during ringing according to ETSI FSK Tariff pulses f=16/12 kHz ; Umin=100mVef on 200 Ω Answer supervision polarity reversal, 12/16 kHz pulses 5.1 SMS Sending Input Closed loop resistance max. 1kΩ Open loop resistance min.
6 6. Supplementary Information This section describes supplementary information of the product. Here is what you can find in this section: Regulations and directives List of Figures Troubleshooting List of Abbreviations.
Regulations and directives 6.1 6.
List of Figures 6.2 6.2 List of Figures Figure 2.1 2N® EasyGate LED indicators ....................................................................................14 Figure 2.2 2N® EasyGate Connectors ........................................................................................14 Figure 2.3 SIM Card Installation ...................................................................................................19 Figure 2.4 2N® EasyGate wall mounting ......................................
Troubleshooting 6.3 6.3 Troubleshooting For tips for the solution of other potential problems see faq.2n.cz. No LED is on after power up Check the power supply. All LEDs are on. No call is currently in progress. EasyGate is in the special PCManager-based programming mode - exit the PCManager to reset EasyGate. Try to switch EasyGate off and on, the LEDs should go off in 3s and signal the status of EasyGate. EasyGate does not register to GSM Check the SIM card. Check the PIN.
List of Abbreviations 6.4 6.
List of Abbreviations 6.
General Instructions and Cautions 6.5 6.5 General Instructions and Cautions Please read this User Manual carefully before using the product. Follow all instructions and recommendations included herein. Any use of the product that is in contradiction with the instructions provided herein may result in malfunction, damage or destruction of the product.
General Instructions and Cautions 6.5 Electric Waste and Used Battery Pack Handling Do not place used electric devices and battery packs into municipal waste containers. An undue disposal thereof might impair the environment! Deliver your expired electric appliances and battery packs removed therefrom to dedicated dumpsites or containers or give them back to the dealer or manufacturer for environmental-friendly disposal.
2N TELEKOMUNIKACE a.s. Modřanská 621, 143 01 Prague 4, Czech Republic Tel.: +420 261 301 500, Fax: +420 261 301 599 E-mail: sales@2n.cz Web: www.2n.cz 1575v1.1.