User guide

Table of Parameters 3.2
37
SMS text Function No.: -
The SMS text to be sent to the preset telephone number. If the SMS text is blank,
an empty SMS is sent.
Setting options: 0-40 characters
Default setting: blank
Send if activated longer than [ms] Function No.: -
Set the SMS activation time necessary for SMS sending. This parameter prevents
SMS sending in the event of short-time activation. If a "0" is selected, SMS is sent
immediately upon the input activation.
Setting options: 0-25500 ms
Setting step: 100 ms
Default setting: 0 ms
Timeout after sending [s] Function No.: -
Set the Time of inactivity after SMS sending. During this timeout no SMS is sent
even if the SMS input gets activated. This prevents sending multiple SMS units in
the case of repeated activation of the input.
Setting options: 0-2550 s
Setting step: 10 s
Default setting: 0 s
GSM & SIM Parameters
GSM operator lock Function No.: -
Provider blocking is set by manufacturer in EasyGate. If EasyGate is blocked to a
GSM provider, no other GSM provider's SIM card can be used. If an unacceptable
SIM card is used, the GSM modules does not registered to GSM and the GSM
network LED flashes quickly on the EasyGate panel.
CLIR - incognito Function No.: 41
Sets the calling line identification restriction (CLIR) for outgoing calls from
EasyGate. Attention, before enabling it is necessary to activate this feature
by GSM operator, otherwise outgoing calls can be rejected by GSM network.
Setting options: -According to provider - depending on how the
function is selected in the GSM network
-Activation - ID is not sent.
-Suppression - ID is always sent
Default setting: According to provider