Manual

142N TELEKOMUNIKACE a.s., www.2n.cz
®
Parameters
Input – define the logic input.
Valid values:
tamper – tamper switch input
input1 – digital input 1
input2 – digital input 2
cr_input1 – digital input 1 on card reader
cr_input2 – digital input 2 on card reader.
There may be different lists of valid values for different 2N Helios IP
®
models; refer to the Available Digital Inputs and Outputs subsection.
Edge – define the detected change on the digital input.
Valid values:
falling – falling edge, change from log. 1 to log. 0
rising – rising edge, change from log. 0 to log. 1.
The parameter is optional, the default value is .rising
Variables
Input the detected ID of the input whose change was the last to generate this
event. The options correspond to the Input parameter values.
Edge the detected edge change which was the last to generate this event. The
options are falling or rising.
Example
Event generated by disconnection of the tamper switch (device opening):
Event.InputChanged: Input=tamper
Event.Delay
The block defines the event generated with a defined delay after anotherDelay
specified event. Define this event to delay the response to the other event by a defined
time interval (Delay).
Parameters
StartEvent – define the event that starts the delay.
StopEvent – define the event that stops the delay. The parameter is optional.
Delay – define the delay time.
Example of valid values:
10 – 10 seconds (units are unnecessary)
10s – 10 seconds
100ms – 100 milliseconds.