Owner's manual

1102N TELEKOMUNIKACE a.s., www.2n.cz
®
3.1 2N® Lift8 Programming
The advantage of the (hereinafter referred to as ) system is that it is2N Lift8
®
L8
programmed via the where all the parameters are stored. Hence, you do not haveCU
to reconfigure anything to replace an Audio Unit and you can program just one inCU
multiple lift systems, for example. The memory is independent of the power.CU
Before You Start
Fill in all the values to be changed in the prepared form with a clear table of basic
functions.
If the is not brand new, make sure that you have the correct servicingL8
password, and if you are not completely sure of your configuration, executeL8
full initialisation (Warning: The servicing password is also initialised!).
L8 can be programmed in 3 ways: remotely via a telephone (telephone number),
using the machine room Audio Unit and/or using the service tool program
(connection via USB/IP address).
Make sure that your telephone supports tone dialling (key phones may cause
problems in some PBXs).
Access to Programming Mode
You can enter the programming mode during an incoming call (calling the number)L8
or using the machine room Audio Unit (press for over 2 seconds).
Use (press 9 for administration and 1 for access to the programming).the voice menu
Upon request, enter the servicing password as follows: (do servicing password
not forget to put an asterisk after the password).
If the password is correct, announces: L8 “You have entered the programming
menu, select a parameter”.
The factory password is 12345 but you are recommended to enter a different password
to protect your device against unauthorised persons.
Caution
Warning: The servicing password is also initialised!
Note
The factory password is 12345 but you are recommended to enter a
different password to protect your device against unauthorised persons.
While entering the password, keep a limit of 60 seconds (or any other
value configured in the range between 10 and 1000 seconds) for each
character to avoid hang-up.L8