Owner's manual

1392N TELEKOMUNIKACE a.s., www.2n.cz
®
4.6 Four-Lift Version
4-Cabin Connection to Internal Splitter
Modify parameter 994 to allow up to 4 cabin s to be connected to the inteaudio unit CU
rnal splitter as lifts 1–4. You can connect the machine room in this mode.audio unit
Set parameter 994 to 1.
Connect up to 4 cabin s.audio unit
Set each cabin to a different type (cabin roof, cabin, cabin bottom,audio unit
shaft bottom) using the adjustable pins (see the cover printing).audio unit
Connect the machine room to the internal splitter if necessary.audio unit CU
Figure: Display of 4-Cabin Connection in Service Tool
Normal 8-Lift Connection
If you set parameter 994 to 0, you can connect up to 8 lift shafts and up to 5 audio
s to each shaft (machine room, cabin roof, cabin, cabin bottom, shaft bottom).unit
Warning
Make sure that each is assigned a different type (cabin roof,audio unit
cabin, cabin bottom, shaft bottom).
Note
You can use a shaft instead of the cabin one.audio unit