Owner's manual

Page 72 Using Menus
360 Systems
WARNING!
Canceling an Export operation during a Replace will cause the file on the external disk to be lost.
9. When the process is complete, the display will show how many files were successfully
exported, how many were skipped, and the total of files processed.
EXPORT FILES
FILES EXPORTED: 7
FILES SKIPPED: 2
FILES IGNORED: 0
FILES WITH ERRORS: 0
TOTAL: 9
PRESS ‘ENTER’ TO CONTINUE
If Replace Files with Same Name was chosen, “Files Skipped” in the display above will
be a count of “Files Replaced”.
Files may be ignored because the External disk is too full or too small to hold that file. If
a file is ignored due to insufficient disk space, the process still continues in case a smaller file is
encountered. Files not exported due to cancellation are also counted as ignored. Errors are
most likely caused by a bad disk or cartridge.
Exported files are given the same name as the Shortcut file with the addition of the file
extension for the chosen format, for example .WAV or .AIF.
10. Upon pressing ENTER, the display reverts to the directory display of the chosen external
directory, so that you can verify that the files are present. Press STOP or EXIT to return to
normal operation.
D-NET File Transmission
D-NET transmission allows you to send files or entire directories to 360 Systems’
DigiCart/II, DigiCart/II Plus or Instant Replay (Original or 2.0). Files recorded at the 48k
sampling rate can optionally be Dolby
AC-2 encoded prior to transmission.
D-NET uses the digital audio outputs to transmit the file name and data. Both the
AES/EBU XLR-3 and AES/SMPTE BNC outputs are active so either one or both can be used.
Transfers from a Shortcut take approximately real time to complete. Due to extensive
differences between the Shortcut and DigiCart/II file formats used by D-NET, transmission
times are longer than between DigiCart/IIs and Instant Replays. Also, as AC2 is not a native
format in Shortcut, that conversion must be done during the transfer, so the time savings for
AC2 does not apply. Some applications may be better performed using the Export function.
Shortcut does not receive D-NET transmissions. Shortcut can be set to Echo D-NET
transmissions to allow two or more Shortcuts to be able to send transmissions to one or more