MULLINS EFFECT
cannot be specified if both the R and M parameters are also specified (use the data line instead to
specify all three parameters). If this parameter is omitted,
will be determined from a nonlinear,
least-squares fit of the test data. A llowable values of BETA are
. The M and BETA param eters
cannot both be zero.
DEPENDENCIES
Set this parameter equal to the num ber of field variables, in addition to temperature, on which the
material parameters depend. If this parameter is omitted, it is assumed that the material parameters
are constant or depend only on temperature. See “S pecifying field variable dependence” in
“Material data definition,” Section 16.1.2 of the ABAQUS Analysis Users Manual, for more
information.
This parameter is not relevant if the USER or the TEST DATA INPUT parameter is included.
M
This parameter can be used only when the TEST DATA INPUT param eter is used; it defines the
value of
while the other coefficients of the Mullins effect model are fitted from the test data. It
cannot be specified if both the R and BETA parameters are also specified (use the data line instead
to specify all three parameters). If this parameter is om itted,
will be determined from a nonlinear,
least-squares fit of the test data. Allowable values of M are
. The M and BETA param eters
cannot both be zero.
PROPERTIES
This parameter applies only to ABAQUS/Standard analyses.
This param eter can be used only if the USER parameter is specified. Set this parameter equal
to the number of property values needed as data i n user subroutine UMULLINS. The default value
is 0.
R
This parameter can be used only when the TEST DATA INPUT param eter is used; it defines the
value of
while the other coefficients of the Mullins effect model are tted from the test data. It
cannot be specified if both the M and BETA parameters are also specified (use the data line instead
to specify all three parameters). If this param eter is omitted,
will be determined from a nonlinear,
least-squares fit of the test data. Allowable values of R are
.
To define the material behavior by giving test data:
No data lines are used with this option when the TE ST DATA INPU T pa rameter is specified.
The data are given instead under the
*
BIAXIAL TEST DATA ,
*
PLANAR TEST D ATA , and
*
UNIAXIAL TEST DATA options. These options are applicable except for the case where the
damage variable is defined by the user.
13.23–2
ABAQUS Version 6.1 Module:
ID: