Two-Way Radio User Manual

*
NODE PRINT
14.11
*
NODE PRINT: Define print requests for nodal variables.
This option is used to provide tabular printed output of nodal variables (displacements, reaction forces, etc.)
in the data file.
Product: ABAQUS/Standard
Type: History data
Level: Step
Reference:
“Output to the data and results files,” Section 4.1.2 of the ABAQUS Analysis Users Manual
Optional parameters:
FREQUENCY
Set this parameter equal to the output frequency in increments. The output will always be printed
at the last increment of each step unless FREQUENCY=0. The default is FREQUENCY=1. Set
FREQUENCY=0 to suppress the o utput.
GLOBAL
This parameter is relevant only at nodes where the
*
TRANSFORM option has been used to define
a local coordinate system.
Set GLOBAL=NO (default) to obtain printout of vector-valued nodal variables in the local
directions.
Set GLOBAL=YES to obtain printout of vect or-valued nodal variables in the global directions.
LAST MODE
This param eter is useful only during eigenvalue extraction for natural frequencies (“Natural
frequency extraction,” Sectio n 6.3.5 of the AB AQUS Analysis Users Manual), complex
eigenvalue extraction (“Complex eigenvalue extraction,” Section 6.3.6 of the AB AQU S Analysis
Users Manual), and eigenvalue buckling estimation (“Eigenvalue buckling prediction,”
Section 6.2.3 of the ABAQUS Analysis Users Manual). Set this param eter equal to the highest
mode number for w hich output is require d.
The default value is LAST MODE=N,whereN is the num ber of modes extracted. If the
MODE param eter is used, the default value is LA ST M ODE= M,whereM is the value of the MODE
parameter.
MODE
This parameter is useful o nly during natural frequency extraction, complex e igenvalue extraction,
and eigenvalue buckling estimation. Set this parameter equal to the first mode number for which
14.11–1