Two-Way Radio User Manual

*
SHELL SECTION
be at least 3, except in a pure heat transfer analysis, where the number of integration points
can be 1 for a constant temperature through the shell thickne ss.
Data lines to define a composite shell (the COMPOSITE parameter is included):
First line:
1. Layer thickness. This value is modified if the NO DAL THICKNESS parameter is included.
2. Number of integration points to be used through the layer. The default is three points if
Simpson’s rule is used and two points if Gauss quadrature is used. The number of integration
points must be an odd number for Simpson’s rule and, in an ABA QUS/Standard analysis,
determines the number of temperature degrees of freedom at a node of the element if this
section is associated w ith heat transfer or coupled tem perature-displacement elements. This
number must be less than or equal to 7 for Gauss quadrature.
3. Name of the material forming this layer.
4. Name of the orientation to be used with this layer or the orientation angle,
, (in degrees)
measured positive counterclockwise relative to the orientation definition given with the
ORIENTATION parameter, where
. If the ORIENTATION parameter is
not included,
is m easured relative to the default shell local directions (see “Orientations,”
Section 2.2.5 of the ABAQUS Analys is Us ers Manual).
Repeat this data line as often as necessary. Use one data line for each layer of the shell. The order of
the laminated shell layers with respect to the positive direction of the shell normal is defined by the order
of the data lines.
18.15–4
ABAQUS Version 6.1 Module:
ID:
Printed on: