Two-Way Radio User Manual

*
SOLID SECTION
Required parameter for anisotropic materials optional parameter for isotropic materials:
ORIENTATION
Set this param eter equal to the nam e given for the
*
ORIENTATION option (“Orientations,”
Section 2.2.5 of the ABAQUS Analysis Users Manual) to be used to define a local coordinate
system for m aterial calculations in the elements in this set. This parameter is required when the
material is anisotropic.
For a composite solid this orientation, tog ether with the orientation angle specified on the lay er
data lines, can also be used to define the materia l orientations in the individual layers. Alterna tively,
a material orientation can be specified by referencing an orientation definition on each layer data line.
In this case the reference given on the ORIENTATION parameter is ignored. Any layer definition
line that does not have an orientation reference or an angle specified will use the section orientation
defined on the key word line.
Optional parameters:
CONTROLS
In an ABAQUS/Explicit analysis, set this param eter equal to the nam e of a section controls
definition (see “Section controls,” Section 21.1.4 of the AB AQU S Analysis Users Manual) to be
used to specify a nondefault hourglass control formulation option or scale factor. The
*
SECTION
CONTROLS option can be used to select the hourglass control and order of accuracy of the
formulation for two- and three-dimensional solid elements and to select the kinematic formulation
for 8-node brick elements.
In an ABA QUS/Standard analysis, set this parameter equal to the name of a section controls
definition (see “Section controls,” Section 21.1.4 of the ABAQUS Analysis Users Manual) to
be used to specify the enhanced hourglass control formulation or to be used in a subsequent
ABAQUS/Explicit import analysis.
STAC K DIRECTION
This parameter applies only to ABAQUS/Standard analyses.
This parameter can be used only with composite elements. It defines the stacking direction
with respect to a pair of element faces. Set this param eter equal to 1, 2, or 3. The default is STACK
DIRECTION=3.
ORDER
This parameter can be used only with acoustic infinite elements in A BAQ US/Explicit. It defines
the number of ninth-order polynomials that will be use d to resolve the variation of the acoustic fie ld
in the infinite direction. Set this parameter equal to N to indicate that the first N members of the set
of ninth-order polynomials are to be used. The default is O RDER=10, w hich is the value always
used in ABAQUS/Standard.
18.22–2
ABAQUS Version 6.1 Module:
ID:
Printed on: