Two-Way Radio User Manual

*
SUBSTRUCTURE LOAD CASE
18.42
*
SUBSTRUCTURE LOAD CA SE: Begin the definition of a substructure load case.
This option is used to begin the definition of a substr ucture load case for the substructure currently being
generated. It can be used only in a
*
SUBSTRUCTURE GENERATE analysis.
Product: ABAQUS/Standard
Type: History data
Level: This option is not supported in a model defined in terms of an assembly of part instances.
References:
“Defining substructures,” Section 10.1.2 of the ABAQUS Analysis Users Manual
*
SLOAD
Required parameter:
NAME
Set this parameter equal to a label that will be used to refer to the load case in
*
SLOAD option
specifications when applying loads to the substructure during an analysis.
To define the loads or boundary conditions:
Enter any mechanical loading options (“Concentrated loads,” Section 27.4.2 of the
ABAQUS Analysis Users Manual, and “Distributed loads,” Section 27.4.3 of the
ABAQUS Analysis Users Manual), thermal loading options (“Thermal loads,” Section 27.4.4
of the ABAQUS Analysis Users Manual), or
*
BOUNDARY options (“Boundary conditions,”
Section 27.3.1 of the ABAQUS Analysis Users Manual) to define the loads form ing the load case.
Specify a magnitude for each load. This magnitude will be scaled by a magnitude and amplitude
reference specified in the
*
SLOAD option. The load case definition continues until an option
is encountered that is not one of the loading options. If boundary conditions are included in a
*
SUBSTRUCTURE LOAD C ASE, they are always active, even if the
*
SLOAD option is not used.
18.42–1
ABAQUS Version 6.1 Module:
ID:
Printed on: