Two-Way Radio User Manual

*
INITIAL CONDITIONS
9.18
*
INITIAL CONDITIONS: Specify initial conditions for the model.
This option is used to prescribe initial conditions for an analysis.
Products: ABAQU S/Standard ABAQUS/Explicit ABAQUS/Aqua
Type: Model data
Level: Model
Reference:
“Initial conditions,” Section 27.2.1 of the ABAQU S Analysis Users Manual
Required parameters:
TYPE
Set TYPE=ACOUSTIC STATIC PRESSURE to define initial static pressure values at acoustic
nodes for use in evaluating the cavitation status of the acoustic elem ent nodes in ABAQUS/Explicit.
Set TYPE=CONCENTRATION to give initial normalized concentrations for a mass diffusion
analysis in ABAQUS/Standard.
Set TYPE=CON TA CT to specify initial bonded contact conditions on part of the slave surface
identified by a node set in an ABAQUS/Standard analysis.
Set TYPE=FIELD to specify initial values of field variables. The VARIABLE parameter can
be used with this parameter to define the field variable num ber. The STEP and INC parameters can
be used in conjunction with the FILE param eter to define initial values of field variables based on
the temperature record of a results file from a previous ABAQUS/Standard heat transfer analysis.
Set TYPE=FLUID PRESSURE to give initial pressures for hydrostatic fluid filled cavities.
Set TYPE=HARDENING to prescribe initial equivalent plastic strain and, if relevant, the
initial backstress tensor or to prescribe initial volumetri c compacting plastic strain for the crushable
foam model. In ABAQUS/Standard the REBAR and USER param eters can be used with this
parameter. If the USER parameter is omitted, ABAQUS/Standard assumes that the initial conditions
are defined on the data lines.
Set TYPE=INITIAL GAP to identify the elements within which tangential fluid flow exists
initially.
Set TYPE=MASS FLOW RATE to specify initial values of mass flow rates in
ABAQUS/Standard heat transfer analyses involving forced convection modeled with the
forced convection/diffusion heat transfer elements.
Set TYPE=PLASTIC STRAIN to specify initial plastic strains. The SECTION POINTS
parameter can be used with this param eter. It is assumed that the plastic strain components are
defined on each data line in the order given for the element type, as defined in Part VI, “Elements,”
of the ABAQUS Analysis Users Manual.