Adjustment Knob Measurement
Adjusting the level plate adjustment knob should initially be performed in
1-step increments. If a ner adjustment becomes necessary, adjust the
knobs in 1/2 step increments.
In the following illustration, the measurement between 1 and 2 is considered
1-step.
Reading the Print Pad Level Calibration Print
Correct Print Pad Level
The Print Pad Level is correct when each of the four (4) corner calibration
points have no gaps between the Print Pad Level calibration lines and the
baselines.
NOTE: Before making any adjustments to the Print Pad Level,
the Z-Gap must be correct.
Incorrect Print Pad Level
In the illustration, there is an incorrect gap between the Print Pad Level
calibration lines and the baselines on the front of the print pad and no gap
between the Print Pad Level calibration lines and the baselines on the back
of the print pad. The front of the print pad needs to be raised.
To correct the Print Pad Level in this instance, turn the front print pad
adjuster knob counter-clockwise (left) 1-step. Reprint the le and verify that
all four corner calibration points are correct.
Acceptable Print Pattern
The Print Pad Level calibration le should print with no gap between the
Print Pad Level calibration lines and the baselines. The illustration indicates
an acceptable print pattern from a prole view.
No Gap
Front
Back
Front
Back
X
1-Step
Side Facing Down
Clockwise Counter-Clockwise