Appendix B
AVI Lane Mapper
IDentity 4100 User Guide
125
Average RSSI Maximum Standard Deviation
> -45 2
-45 < and > -55 4
-55 < and > -65 6
-65 < 8
h Prompt between Polling Intervals – Selects a Prompt Monitoring
Session. A message box to displayed at the start of the session and
between each polling interval. Press
OK
on the message box to start the
next polling interval. This is the default Monitoring Session type.
h Automatic – Selects an Automatic Monitoring Session. When the
monitoring session starts, the application waits for the amount of time
specified in the
Next Interval Wait Time
field before starting the polling
interval for the first grid square. If a sound file is specified, it will sound
at the end of the polling interval and the applications will wait again
until the next polling interval is started.
h Next Interval Wait Time – Amount of time the application will wait
between polling intervals in seconds. This value needs to be greater
than 1. The default for this option is 15.
h Select next square to be polled – Selects the User Selects Monitoring
Session. A dialog is displayed at the start of the session and between
each polling interval to allow you to select the next square to be polled.
Press
OK
on the dialog to start the next polling interval.