User's Manual

Table Of Contents
1 2 3 4
5
6 7 8 9
Reader Startup Tool
IDentity 5200 User Guide
25
Tag read controls are provided by the
Polling
and
Scan Operation
blocks.
Use the
Polling
controls when the reader is in active mode. Use the
Scan
Operation
controls when the reader is in standby mode.
Tag and reader performance data is provided in the
Performance
Information
and
Tag Acquisition Analysis
blocks.
Performance Information
Total Unique Tags
– Number of unique tags in the tag database.
Tag Read Count
– Total number of tags reader (including repeat reads).
Cumulative rate
– Cumulative read rate in tags/second since the
Start
button was pressed.
Current rate
– Current read rate in tags/second.
Purge and Clear State
– Press to clear the current display and reset the
statistics reporting.
Polling
Polling Interval
Amount of time (ms) to wait between each poll for data.
Polling Interval
Total amount of time (ms) to poll for data (1 to 10 sec).
Start –
Click this button to poll the tag database every
Polling Inte
rval (ms)
for a total time of
Total Polled Time (ms).
Do not set the interval less than
500. If Total Polled Time is set to 0, polling continues indefinitely.
Stop –
Click this button to stop automatic polling.
Get Once
Click this button to retrieve the current information from the
reader’s tag database.
Purge every poll –
Check this option to purge the reader’s tag database
after each poll. Refer to the INfinity 510 Protocol Reference Guide for more
information on the tag database.
Beep On –
Indicates current read rate with audible tone.
Tag Acquisition Analysis
The
Tag Acquisition Analysis
fields provide the minimum, maximum, and
average number of times each tag was read. For example, assume five tags
(A, B, C, D, and E) are read 107, 59, 223, 187, and 94 times respectively.
The displayed values are as follows:
Min
= 59
Avg
= 134
Max
= 223
Scan Operation
Scan time (ms)
– Enter the duration of reader operation in milliseconds.
After this time expires, the tag information is displayed.
Scan Tags
– Press this button to activate the reader.