User's Manual

December 6, 2006 Proprietary Information 7
Revision 1.0
2.2 Electrical Specifications
Table 1 IDentity MaX Mobile reader Pin Definitions
Pin Number Pin Description
1
No Connection
2
RXD – Receive Serial Data
3
TXD – Transmit Serial Data
4
No Connection
5 Ground
6
No Connection
7
No Connection
8
No Connection
9
No Connection
Input voltage 120 VAC 60 Hz / 5VDC, 2A max
RF output power 30dBm
Frequency UHF band, 902 - 928 MHz
Communications Protocol Serial with CCITT CRC-16 error detection
Communications Parameters 115200 bps, 8 data bits, no parity, 1 stop bit
Communications Signal Level Serial data at RS-232 logic levels
Regulatory FCC Part 15