Safety Data Sheet

3M Air Tool Lubricant 05/14/15
__________________________________________________________________________________________
Page 5 of 10
None required.
Skin/hand protection
Select and use gloves and/or protective clothing approved to relevant local standards to prevent skin contact based on the
results of an exposure assessment. Selection should be based on use factors such as exposure levels, concentration of the
substance or mixture, frequency and duration, physical challenges such as temperature extremes, and other use conditions.
Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible gloves/protective
clothing. Note: Nitrile gloves may be worn over polymer laminate gloves to improve dexterity.
Gloves made from the following material(s) are recommended: Polymer laminate
If this product is used in a manner that presents a higher potential for exposure (eg. spraying, high splash potential etc.), then
use of protective coveralls may be necessary. Select and use body protection to prevent contact based on the results of an
exposure assessment. The following protective clothing material(s) are recommended: Apron - polymer laminate
Respiratory protection
An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of
a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator
type(s) to reduce inhalation exposure:
Half facepiece or full facepiece air-purifying respirator suitable for organic vapors and particulates
For questions about suitability for a specific application, consult with your respirator manufacturer.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
General Physical Form:
Liquid
Odor, Color, Grade:
Mild pretroleum odor, clear light amber liquid
Odor threshold
No Data Available
pH
No Data Available
Melting point
Not Applicable
Boiling Point
230 ºC
Flash Point
138 ºC [Test Method: Pensky-Martens Closed Cup]
Evaporation rate
No Data Available
Flammability (solid, gas)
Not Applicable
Flammable Limits(LEL)
No Data Available
Flammable Limits(UEL)
No Data Available
Vapor Pressure
No Data Available
Vapor Density
No Data Available
Density
No Data Available
Specific Gravity
0.88 [@ 20 ºC] [Ref Std: WATER=1]
Solubility in Water
Nil
Solubility- non-water
No Data Available
Partition coefficient: n-octanol/ water
No Data Available
Autoignition temperature
No Data Available
Decomposition temperature
No Data Available
Viscosity
35.4 centistoke [@ 40 ºC ] [Test Method: Tested per ASTM
protocol] [Details: 10 wt. D-445]
Viscosity
6.1 centistoke [@ 100 ºC ] [Test Method: Tested per ASTM
protocol] [Details: 10 wt. D-445]
Volatile Organic Compounds
71.5 % [Details: Calculated]
Percent volatile
71.5 % [Details: Calculated]
VOC Less H2O & Exempt Solvents
715 g/l [Details: Calculated]
SECTION 10: Stability and reactivity