3M™ Benchtop Air Ionizer 963E User’s Guide 1
Table of Contents Section Page Safety Information.................................................................................................3 1. Description.........................................................................................................4 2. Performance.......................................................................................................4 3. Power Requirements...........................................................................................4 4.
SAFETY INFORMATION The 3M™ Benchtop Air Ionizer 963E is designed to generate and deliver a stream of ionized air. Its intended use is to neutralize excess static electricity buildup on electronic devices and work surfaces. It is meant to function as a stand alone device. The Ionizer 963E is not intended to take the place of proper grounding of personnel as the preferred method of controlling electrostatic buildup and preventing hazardous discharge.
1.0 Description The 3M™ Benchtop Air Ionizer 963E is a self-contained ionizing air blower designed to remove static charges from non-conductive objects. The proprietary circuitry contained in the blower generates balanced levels of positive and negative ions. The Ionizer 963E is equipped with a two speed fan which allows the user to select the amount of ionized air to be delivered to the target object.
.0 Operation The three position rocker switch on the front of the unit is the POWER switch. The center switch position (marked O) is the OFF position. The upper and lower switch positions (marked II and I) turn the unit on to HIGH and LOW fan speeds. Use this switch to turn the unit on and to select the desired fan speed. A green monitor light is also illuminated respectively on the front of the unit, which indicates that the power switch is in one of the ON positions, and that the ionizer is now in use.
7.21 Attach the flat plate electrode to the 3M™ Charge Analyzer 711. Refer to the owner’s manual for the Analyzer 711 for complete operating instructions. 7.22 Place the Analyzer 711 on its side allowing for viewing of the display. Position the Analyzer 711 so that the plate is parallel to the ionizer at a distance of one foot. The plate of the Analyzer 711 should be centered (up & down, left & right) in the air stream.
8.0 3M™ Benchtop Air Ionizer 963E Physical Characteristics Item Typical Property Power Ratings 24VDC, 0.42A through included universal power transformer Power Inlets Mini DIN Socket Power Transformer Input: 100V–240VAC, 0.8A, 50/60 Hz into IEC320 Socket Output: 24VDC, 1.0A 6 ft. (1.8m) cord with Mini DIN plug Dimensions (with mounting base) 8.5 in. W x 9 in. H x 4.5 in. D (21.6 cm W x 22.9 cm H x 11.4 cm D) Air Velocity** low speed - 100 fpm (0.5 m/s) high speed - 300 fpm (1.
Regulatory Information FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
RoHS 2011/65/EU” means that the product or part does not contain any of the substances in excess of the maximum concentration values (“MCVs”) in EU RoHS Directive 2011/65/EU. The MCVs are by weight in homogeneous materials. This information represents 3M’s knowledge and belief, which may be based in whole or in part on information provided by third party suppliers to 3M. 3M is a trademark of 3M Company.