Cut Sheet
8882 High Gel, Part B 09/10/14
__________________________________________________________________________________________
Page 3 of 8
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Evacuate area. Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation
to disperse or exhaust vapors, in accordance with good industrial hygiene practice. Warning! A motor could be an ignition
source and could cause flammable gases or vapors in the spill area to burn or explode. Refer to other sections of this SDS for
information regarding physical and health hazards, respiratory protection, ventilation, and personal protective equipment.
6.2. Environmental precautions
Avoid release to the environment. For larger spills, cover drains and build dikes to prevent entry into sewer systems or
bodies of water.
6.3. Methods and material for containment and cleaning up
Contain spill. Working from around the edges of the spill inward, cover with bentonite, vermiculite, or commercially
available inorganic absorbent material. Mix in sufficient absorbent until it appears dry. Remember, adding an absorbent
material does not remove a physical, health, or environmental hazard. Collect as much of the spilled material as possible.
Place in a closed container approved for transportation by appropriate authorities. Clean up residue with an appropriate
solvent selected by a qualified and authorized person. Ventilate the area with fresh air. Read and follow safety precautions on
the solvent label and SDS. Seal the container. Dispose of collected material as soon as possible.
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Avoid eye contact. For industrial or professional use only. Avoid breathing dust/fume/gas/mist/vapors/spray. Do not eat,
drink or smoke when using this product. Wash thoroughly after handling. Avoid release to the environment. Avoid contact
with oxidizing agents (eg. chlorine, chromic acid etc.)
7.2. Conditions for safe storage including any incompatibilities
Store away from heat. Store away from oxidizing agents.
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Occupational exposure limits
If a component is disclosed in section 3 but does not appear in the table below, an occupational exposure limit is not available
for the component.
Ingredient C.A.S. No. Agency Limit type Additional Comments
Hydrotreated heavy naphthenic
petroleum distillates
64742-52-5 CMRG TWA:5 mg/m3;STEL:10
mg/m3
ACGIH : American Conference of Governmental Industrial Hygienists
AIHA : American Industrial Hygiene Association
CMRG : Chemical Manufacturer's Recommended Guidelines
OSHA : United States Department of Labor - Occupational Safety and Health Administration
TWA: Time-Weighted-Average
STEL: Short Term Exposure Limit
CEIL: Ceiling
8.2. Exposure controls
8.2.1. Engineering controls
Curing enclosures must be exhausted to outdoors or to a suitable emission control device. Use general dilution ventilation
and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control
dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment.
8.2.2. Personal protective equipment (PPE)