Fire Barrier Cast-In Devices
It accommodates,adjusts, adaptsand conforms.
Firestopping pipe through concrete has
never been easier, thanks to 3M
™
Fire
Barrier Cast-In Devices. This remarkable
system adjusts to any height between 2-1/2"
and 8", and with the 3M Height Adaptor, it
can adapt to any depth of concrete pour.
It works for both metallic and non-metallic
pipe
, vented or closed piping systems,
and can firestop for up to three hours.
Installation is done before the concrete is
poured. The device can be used on flat
forms. Or when used in conjunction with the
3M Fluted Metal Deck Adaptor, the device
can be attached to a fluted metal deck.
Once the concrete cures, the pipe can be
passed through.
Gr
ab tear strip with pliers. Complete tear and remove. Secure to decking.
Layout of devices. Pour concrete. Finished concrete over device.
Building Saf
ety Solutions De
par
tment
3M Center, Bldg. 223-2S-24
St.
P
aul,
MN 55144-1000
Ph.
800-328-1687
www.3m.com/firestop
Break cap. Remove cap. Install pipe.
W
arranty and Limited Remed
y
.
This product will be free from def
ects in mater
ial and man
uf
acture
for a period of ninety (90) days from date of purchase. 3M MAKES NO OTHER WARRANTIES
INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A P
AR
TICULAR PURPOSE. User is responsible for determining whether the 3M
product is fit for a particular purpose and suitable for user’s application. If the 3M product is proved
to be defective within the warranty period stated above, your exclusive remedy and 3M’s sole
ob
ligation shall be
, at 3M’
s option, to replace or repair the 3M product or refund the purchase pr
ice
of the 3M product.
Limitation of Liability. Except where prohibited by law, 3M will not be liable for any loss or
damage from a 3M product, whether direct, indirect, special, incidental or consequential,
regardless of the legal theory asserted, including warranty, contract, negligence
or strict liability.
SHIPPING INFORMATION
Product Shpg. Wt. Per Packaging Price
Product Number Description Carton Lbs. UPC Number Per Case Per Pallet Unit
2PCID 2" diameter 11.44 000-51115-16536-8 12 420 each
3PCID 3" diameter 17.00 000-51115-16537-5 12 240 each
4PCID
4" diameter 12.43 000-51115-16538-2 6 180 each
6PCID 6" diameter 21.00 000-51115-16539-9 2 70 each
Cast-In De
vices
2MCID
2" diameter
11.56 000-51115-16540-5 12 420 each
for Metal Pipes 3MCID 3" diameter 15.34 000-51115-16541-2 12 240 each
4MCID 4" diameter 19.82 000-51115-16542-9 6 180 each
6MCID 6" diameter 16.50 000-51115-16543-6 2 70 each
Cast-In Devices
for Plastic Pipes
FIREST
OP DEVICES
FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS
SEE UL DIRECT
OR
Y OF PR
ODUCTS CERTIFIED FOR CANADA
AND UL FIRE RESISTANCE DIRECTORY
90G8
C
C
L
L
A
A
S
S
S
S
I
I
F
F
I
I
E
E
D
D