Drawing

Table Of Contents
3M™
Medium-Wall Heat Shrink Tubing IMCSN
2 of 5
Characteristics
and Test Data
Property
Requirements*
Test Results
Continuous Operating
Temperature Range
-55°C to 110°C -55°C to 110°C
Color Black Black
Longitudinal Change + 1%, - 10% Pass
Low Temperature Flexibility
(4 hours @ -55°C)
No Cracking Pass
Heat Shock
(4 hours @ 255°C)
No Cracking, Flowing
or Dripping
Pass
2% Secant Modulus 25,000 psi max. 14,000 psi
Color Stability
(24 hours @ 175°C)
Remain Stable Pass
Tensile Strength 1,200 psi min. 2,400 psi
Ultimate Elongation 200% min. 475%
Dielectric Strength (V/mil) 200 min. 500
Volume Resistivity (ohm-cm) 1 0
1 3
min. 1 0
1 4
*Based on MIL-I-23053/15A Class 2
Fluid Resistance /
MIL-I-23053
Minimum tensile strength, 750 psi.
Minimum dielectric strength, 200 V/mil.
Twenty-four hours at 25°C.
Fluids
Tensile Strength
Dielectric Strength
Hydraulic Fluid Pass Pass
JP-4 Fuel Pass Pass
Lube Oil Pass Pass
5% NaCl Solution Pass Pass
Deicing Fluid Pass Pass
Engineering /
Architectural
Specifications
The tubing must be usable both indoors and outdoors, in overhead, direct-buried, or
submerged applications on cables rated up to 1000 volts. It is not adversely affected by
moisture, mild acids and alkalies, fuels, oils, ozone, or ultraviolet light. It must be compatible
with and adhere to all types of cable jackets, including rubber, plastic, or lead. It must
conform to the requirements of UL 486 D and sections 3.4 and 4.3 of ANSI C119.1 1986.