User Guide

3M
Infrared Thermometers
Specifications Models
IR-500 IR-999 IR-1100 IR-1400
Temperature Range 0 to 500°F -25 to 999°F -25 to 1100°F -25 to 1400°F
(-18 to 260°C) (-32 to 535°C) (-32 to 600°C) (-32 to 760°C)
Accuracy of Reading ±2% ±1% ±1% ±1%
Repeatability of Reading ±2% ±0.5% ±0.5% ±0.5%
95% Response Time 500 msec 500 msec 500 msec 500 msec
Spectral Response 7-18 microns 8-14 microns 8-14 microns 8-14 microns
Optical System 8:1 12:1 30:1 50:1
MAX Temperature X X X
MIN, DIF, AVG Temp X X
Recall Last Reading X X
Display Hold X X X X
HI Alarm X X
LO Alarm X X
Low Battery Indicator X X X X
LCD Backlight X X X X
Laser (Class II) X X X X
Emissivity Pre-set 0.95 Pre-set 0.95 Adjustable Adjustable
from 0.10 to 1.0 from 0.10 to 1.0
Temperature Display °C or °F selectable °C or °F selectable °C or °F selectable °C or °F selectable
3.5 digit LCD 3.5 digit LCD 3.5 digit LCD 3.5 digit LCD
Display Resolution 0.5°F (0.2°C) 0.1°F (0.1°C) 0.1°F (0.1°C)
Ambient Operating Range 32 to 120°F 32 to 120°F 32 to 120°F 32 to 120°F
(0 to 50°C) (0 to 50°C) (0 to 50°C) (0 to 50°C)
Relative Humidity, 10-95% RH 10-95% RH 10-95% RH 10-95% RH
ambient noncondensing, noncondensing, noncondensing, noncondensing,
@ > 86°F (30°C) @ > 86°F (30°C) @ > 86°F (30°C) @ > 86°F (30°C)
Storage Temperature -13° to 158°F -13° to 158°F -13° to 158°F -13° to 158°F
(-20° to 60°C) (-20° to 60°C) (-20° to 60°C) (-20° to 60°C)
w/out battery w/out battery w/out battery w/out battery
Power 9V Alkaline 9V Alkaline 9V Alkaline 9V Alkaline
or NiCd battery or NiCd battery or NiCd battery or NiCd battery
Battery Life (Alkaline) 12 hours 10 hours with laser and backlight on 20 hours with laser and backlight on 50%
40 hours with laser and backlight off 40 hours with laser and backlight off
Dimensions 7.25 x 1.75 x 1.5 in 8 x 6 x 2 in 8 x 6 x 2 in 8 x 6 x 2 in
(184 x 45 x 38 mm) (200 x 160 x 55 mm) (200 x 160 x 55 mm) (200 x 160 x 55 mm)
Weight 8 oz. (227g) 11 oz. (320g) 11 oz. (320g) 11 oz. (320g)
Locking Trigger X X
Tripod Mount 1/4”-20 UNC 1/4”-20 UNC 1/4”-20 UNC
Threading Threading Threading
Accessories Standard Hard plastic case Hard plastic case Hard plastic case
With Each Unit Wrist strap Wrist strap Wrist strap
Data Logger Points 12 data points in 12 data points in
memory memory
* NIST and DKD certification is optional on all models except the IR-500.
** The IR-60CFO thermometers has the same specifications as the IR-60L2 and IR-60EXCFO have the same specifications as the IR-60EXPL2 thermometer.
*** The IR-1400IS thermometers has the same specifications as the IR-1400 thermometers.
3M
Infrared Thermometers (cont.)
IR-60L2 IR-60EXPL2
-25 to 1600°F -25 to 1600°F
(-32 to 870°C) (-32 to 870°C)
±1% ±1%
±0.5% ±0.5%
250 msec 250 msec
8-14 microns 8-14 microns
60:1 60:1
X X
X
X X
X X
X X
X
X X
X X
3 dot vertical line 3 dot vertical line
Adjustable Adjustable
from 0.10 to 1.0 from 0.10 to 1.0
°C or °F selectable °C or °F selectable
3.5 digit LCD 3.5 digit LCD
Tenth degree reading up to Tenth degree reading up to
199.9 (F or C) 199.9 (F or C)
32 to 120°F 32 to 120°F
(0 to 50°C) (0 to 50°C)
10-95% RH 10-95% RH
noncondensing, noncondensing,
@ > 86°F (30°C) @ > 86°F (30°C)
-25° to 122°F -25° to 122°F
(-30° to 50°C) (-30° to 50°C)
w/out battery w/out battery
2 x 1.5V alkaline Type AA 2 x 1.5V alkaline Type AA
25 hours measurement mode, 11 hours with laser on, 6 hours with
backlight and laser on (50% backlight used)
6.7 x 2 x 7.9 in 6.7 x 2 x 7.9 in
(170 x 50 x 200 mm) (170 x 50 x 200 mm)
1 lb - 6 oz. 1 lb - 6 oz.
X X
1/4”-20 UNC 1/4”-20 UNC
Threading Threading
Hard plastic case Software, RS232 cable,
Wrist strap 7.5 V power supply, contact probe
Hard plastic case, wrist strap
100 points in memory
IR-500
IR-999
IR-1100/1400/1400IS
IR-60L2/60CFO
IR-60EXPL2/60EXCFO