User Guide

314* Moisture 0.155" (3,94 mm) 22-14 (0,5-1,5) 105°C (221°F)
Resistant Seal
314U* Dry Environment 0.155" (3,94 mm) 22-14 (0,5-1,5) 105°C (221°F)
Applications
316IR Moisture Resistant 0.155" (3,94 mm) 22-16 (0,5-1,5) 105°C (221°F)
Applications
557* Dual Element 0.120" (3,05 mm) 22-16 (0,5-1,5) 105°C (221°F)
Connection
558* Flame 0.120" (3,05 mm) 22-16 (0,5-1,5) 105°C (221°F)
Retardant
560 Flame 0.145" (3,68 mm) 18-16 (0,75-1,5) 105°C (221°F)
Retardant Solid/Stranded
14 Stranded
560B Run & Tap 0.145" (3,68 mm) 18-16 (0,75-1,5) 90°C (194°F)
Splicing Solid/Stranded
14 Stranded
560N Flame 0.145" (3,68 mm) 18-16 (0,75-1,5) 105°C (221°F)
Retardant Solid/Stranded
14 Stranded
562 Run & Tap 0.190" (4,82 mm) 12-10 (3,0-4,0) 90°C (194°F)
Splicing Solid/Stranded
10 Stranded
564 Dry Environment 0.145" (3,68 mm) 18-14 (0,75-1,5) 90°C (194°F)
Applications
567 Dual Element 0.145" (3,68 mm) 18-14 (0,75-1,5) 105°C (221°F)
Connection Tap Tap
0.190" (4,82 mm) 12-10 (3,0-4,0)
Run Run
804 Moisture 0.145" (3,68 mm) 18-16 (0,75-1,5) 75°C (167°F)
Resistant Solid/Stranded
Applications 14 Stranded
804U Dry Environment 0.145" (3,68 mm) 18-16 (0,75-1,5) 75°C (167°F)
Applications Solid/Stranded
14 Stranded
901 Disconnect 0.145" (3,68 mm) 18-14 (0,75-1,5) 90°C (194°F)
905 Low Voltage 0.110" (2,79 mm) 22-18 (0,5-1,0) 90°C (194°F)
(Automotive) Tap Tap
Applications 0.145" (3,68 mm) 18-14 (0,75-1,5)
Run Run
905N Low Voltage 0.110" (2,79 mm) 22-18 (0,5-1,0) 90°C (194°F)
(Automotive) Tap Tap
Applications 0.145" (3,68 mm) 18-14 (0,75-1,5)
Run Run
951 T-Tap Disconnect 0.150" (3,81 mm) 22-18 (0,5-1,0) 105°C (221°F)
952 T-Tap Disconnect 0.150" (3,81 mm) 18-14 (0,75-1,5) 105°C (221°)
953 T-Tap Disconnect 0.150" (3,81 mm) 12 (3,0) 105°C (221°)
972 Fuse Holder 0.150" (3,81 mm) 18-14 (0,75-1,5) 90°C (194°F)
Type Special Maximum AWG (mm
2
) Operating UL, CSA or CE
Connector Connector Features Insulation Wire Range Temperature Certified
IDCs for Electrical Applications
*
Also tested in accordance with UL Standard for Portable Electric Lamps, UL 153 paragraph 15, when housed within the body of the lamp.