Cut Sheet
Scotchlok
™
Terminals
MVU18-187DM, MVU14-187DM
Male Disconnect, Vinyl Insulated, Butted Seam
Data Sheet
Specifications
Wire Size: See Table Above
Barrel Seam: Butted
Max. Voltage Rating: 600 V Building Wire
1000 V Signs or
Fixtures (Luminaires)
Max.Temperature Rating: 221˚F (105˚C)
Max. Current: Same as Wire
Insulator Material: Vinyl
Terminal Material: ETP Copper
Plating: Tin
Installation Information
UL Listed and CSA Certified for use on stranded copper
(AWG) wire only.
Strip away the end 3/8 inch of wire insulation.
Make the crimp in the proper station of a recommended 3M
crimp tool: TH-440, TH-450 (scissor style) hand tools, or
TR-490 (ratchet style) hand tools.
Barrel Crimp (Required)
W«
L
Suitable for factory application on steel or brass tabs UL or
CSA.
Suitable for field application on brass tabs, strain relief
required, UL only.
UNDERWRITERS
LABORATORIES
STANDARD NO. UL 310
3M FILE NO. E70512
CANADIAN STANDARDS
ASSOCIATION
STANDARD NO. C22.2
NO. 153
3M FILE NO. LR22190
W´
WARNING
Turn power off before installing or removing terminal. All electrical
work should be done according to appropriate electrical codes.
rebmuNtcudorP
egnaReriW
)GWA(
baTelaM
)´W(htdiW
ssenkcihTxL
lerraB
htgneL
lerraB
.D.I
mumixaM
noitalusnI
retemaiD
MD781-81UVM81-22020.0x781.058.042.0080.0541.0
MD781-41UVM41-61020.0x781.058.042.0080.0541.0