User's Instructions
11
Table 1 – Specications
Nano-Lok Self-Retracting Device (Figure 2.2):
Figure
Reference Component Materials
A Lifeline Dyneema webbing
B Energy Absorber Polyester webbing
C
Housing Blue super-tough nylon plastic
D
Swivel Alloy steel
E Cab Mount Alloy steel
Connected Aluminum Carabiner (Figure 2.3):
Figure
Reference Component Materials
A Connection Eye 7075 Aluminum alloy
B Gate 7075 Aluminum alloy
C
Shroud Black polycarbonate/PBT plastic
Performance Specications:
Electrical Power (Connected Sensor Box):
Recommended Operating Voltage: 24 VDC
Minimum Operating Voltage: 12 VDC
Maximum Operating Voltage: 26 VDC
Current Requirement: 200 mA at 24 VDC; 400 mA at 12 VDC
SRD Specications (Z359.14 Class B) ANSI OSHA
Capacity Range 130 lbs - 310 lbs (59 kg - 140 kg) 130 lbs - 420 lbs (59 kg - 191 kg)
Maximum Arresting Force 1,350 lbs (6.0 kN) 1,350 lbs (6.0 kN)
Average Arresting Force 900 lbs (4.0 kN) 900 lbs (4.0 kN)
Arrest Distance 42 in (1.07 m) 42 in (1.07 m)
Minimum Fall Clearance Required
1
6.0 ft (1.83 m) 6.0 ft (1.83 m)
Maximum Free Fall
2
2.0 ft (0.6 m) 2.0 ft (0.6 m)
1 - Assumes the SRD is mounted directly above (overhead) the end user.
2 - SRD must be mounted above user D-ring.
RF Regulatory Information (FCC Rules and ISED):
FCC ID: DGFPSD3100273
IC: 485A - PSD3100273
This device complies with Part 15 of the FCC Rules and with the license-exempt RSS(s) of Innovation, Science and Economic Development
(ISED) Canada. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
The 3M™ DBI-SALA® Connected Order Picker SRD System is designed to meet the regulatory requirements in those jurisdictions in which it
is offered. Changes or modifications not expressly approved by 3M Company could void the user’s authority to operate the 3M™ DBI-SALA®
Connected Order Picker SRD System.
Cet appareil est conforme à la partie 15 des règles de la FCC et aux CNR applicables aux appareils exemptés de licence d’Innovation,
Sciences et Développement économique Canada (ISED). Le fonctionnement est assujetti aux deux conditions suivantes:
1) cet appareil peut provoquer des interférences nuisibles;
2) cet appareil doit accepter toute interférence reçue, y compris les interférences qui peuvent causer un fonctionnement indésirable.
Le système de dispositif autorétractable pour manutentionnaires connecté DBI-SALA® 3M
MC
a été conçu conformément aux exigences
réglementaires des territoires de compétence dans lesquelles il est offert. Tout changement ou modification non expressément approuvé par
3M peut annuler le droit de l’utilisateur d’utiliser le système de dispositif autorétractable pour manutentionnaires connecté DBI-SALA® 3M
MC
.