Operation mode
You can set the SelfCheck system to three modes of operation:
Normal
In Normal mode the system is communicating with the
circulation system and checking in library items.
Offline
Offline mode enables the SelfCheck system to operate when
the library's circulation system is not functioning. Offline
transaction data are stored in the SelfCheck system for
forwarding to the circulation system when the two systems are
communicating again.
Operation modes
Out of Service
Select Out of Service to disable the system. In Out of Service mode no
items are stored for forwarding at a later time.
To select an operation mode
In the Operation Mode box, click the operation mode you want, and
then click Set Mode.
Logging
The log is used for troubleshooting. In the Logging section
you can turn logging on and off, select how much information
is logged, view logs, and save logs on your computer. You
should leave the log level set to INFO unless 3M support
personnel request you to change it.
To turn on logging
1 Click the Log Level box, and then click the logging level
you want. Each level includes all levels below it except
OFF.
2 Click Set Level.
Log levels
To turn off logging
1 Click the Log Level box, and then click OFF.
2 Click Set Level.
To display the current log
Click View Log. The log is displayed in your browser.
To save the current log
1 Click Download Log.
2 In the File Download dialog box, click Save.
3 In the Save As dialog box, rename the log file as needed, navigate to
the folder where you want to save the file, and then click Save.
Configuration submission
See “Configuration submission” on page 25.