User's Manual

Page 42 of 56
RTE8000 HS Evaluators' Guide 97-0183-15.doc
The storage space required for an image depends on the compression level. The following table shows the
sizes in Kilobytes of different full size images at different qualities:
Full size image
Best Quality (KB)
Compression = 0
Lower Quality (KB)
Compression = 70
IR full image 520 44
IR codeline only 300 26
UV colour 700 39
Visible colour 860 75
Photo 230 20
The compression settings can be modified by selecting the ‘Data To Send’ screen in the High Level Test
Container ‘Settings’ menu option or using the schemes configuration in the Page Reader Expo. If modifying
directly, the settings can be found in the initialisation file Reader.ini in the [DataToSend] section.
If all images are saved ensure that there is enough hard disk space as the storage space requirement soon
adds up as more and more documents are scanned.
5.2.1.3 Sound Scheme
The sound settings are fully customisable by editing the sound.ini file which is used to configure the sound
scheme and individual sounds. There are three available sound schemes namely effects, speech and beeps.
The following events can trigger sounds in the scanner:
•
Read success
•
Read error
•
Error
•
No Connection
•
Read mode
•
Update mode
•
Configuration mode
The effects and speech sound schemes play appropriately named .wav files, which reside on the flash disk
within the scanner. These files could be replaced by other .wav files if desired, for example, the speech scheme
files might be replaced by speech files in other languages.
Note: the sounds are played on the PC that is running application and not from
the scanner hardware.