44
13-MAINTENANCE AND REPAIRS (continued)
2012 March
800rf-NA
To reduce the risk associated with
mechanical and electrical hazards:
Turn electrical and air supply off and
disconnect before performing any
adjustments, maintenance or servicing
the machine or taping heads
WARNING
Remove the locking screws and the protection
covers.
Loosen the tensioning screws.
Release the nut of the tensioning plate.
Remove and replace the drive belt.
Important Before setting the new belt, check the
wear of the orange plastic rings on the drive
pulleys: replace them if they are worn out.
Figure 13-9
Figure 13-10
Figure 13-11
Figure 13-12