User's Manual

Octopus ATM Defense System
Installation and Operation Guide
Page A2
AREA WORD ERROR
CODE
AREA ERROR ERROR CONDITION
MCU INTERNAL SENSOR
1000 1001 MCU battery low
1000 1010 MCU tilt error
1000 1011 MCU thermal error
MCU EXTERNAL INPUTS
1100 1001 Generic NC input # 1 error
TEST MODE ONLY Power Loss (No V+) indicator
1100 1011 Generic NO input #1 error
1100 1100 Generic NC input # 2 error
TEST MODE ONLY DOOR closed indicator
1100 1110 Generic NO input # 2 error
1100 1111 Manual Fire NC/Breach error
TEST MODE ONLY All Safe signal activated indicator
CSU ONBAORD SENSORS
1110 1001 CSU battery low
1110 1010 CSU tilt error
1110 1011 CSU squib error
1110 1100 CSU thermal error
Table 1. BIST Error Readout Indication Matrix
Error Possible Cause
MCU Low Battery a) Low battery – replace
b) Faulty electronics – new unit required
MCU Tilt Error a) MCU is in horizontal position and jumper J22 (H/V)
is removed.
b) MCU is in vertical position or upside down and
jumper J22 (H/V) is installed.
MCU Thermal Error a) Unit is too hot > 70 ºC.
b) Unit is too cold < 0 ºC.
Generic NC input # 1 error a) Sensor Array cable pin # 7 is not shorted to ground
when connected.
b) Contacts reversed so that unit ground and ATM
chassis ground are not common.
c) Faulty RJ45 plug.
Generic NO input # 1 error a) Sensor Array cable pin # 7 is not open to ground
when connected.
b) Contacts reversed so that unit ground and ATM
chassis ground are not common.
c) Faulty RJ45 plug.
Generic NC input # 2 error a) Terminal block J31 is not shorted when connected.
b) Contacts reversed so that unit ground and ATM
chassis ground are not common.
c) Wire gauge too small.
Generic NO input # 1 error a) Sensor Array cable pin # 1 is not open to ground
when connected.
b) Contacts reversed so that unit ground and ATM
chassis ground are not common.
c) Wire gauge too small.
Manual Fire NC / Breach error a) Sensor Array cable pin # 2 is not shorted to ground
when connected or Terminal Block J10 not shorted
when connected.
b) Contacts reversed so that unit ground and ATM
chassis ground are not common.
a) Faulty RJ45 cable or wire gauge too small.