User's Manual

Octopus ATM Defense System
Installation and Operation Guide
Page J1
Appendix J
Mode Jumper Selection
On both the MCU and CSU two of jumpers provided to allow for selecting mode of operation. Addressed
first is the H/V jumper. These jumpers are currently not populated.
If the H/V jumper is installed the unit must be placed horizontal with electronics facing downwards !
There are two other jumpers for selecting operating mode. On the MCU these jumpers are J25 and J26.
On the CSU these jumpers are J13 and J14. In order to change these configurations the unit battery must
be removed for a complete power-on reset. Table 5 below details the mode differences and Figure 6 shows
the physical location of the jumpers on the MCU and CSU.
MCU Jumpers Mode Differences from normal operation
J25 J26
off off LEVEL
IV (US)
Operation as described within this document (US VERSION).
off on LEVEL
III (CA)
Operation as described within Appendix J (LEVEL III CA VERSION)
on off LEVEL
V (BZ)
Operation as described within Appendix K (LEVEL V BZ VERSION)
on on LEVEL
II
OPERATION NOT DEFINED
CSU Jumpers
J13 J14
off off Normal Operation as described within this document (US VERSION).
off on Not
Assigned
on off LEVEL
V (BZ)
Operation as described within Appendix K (BRAZIL VERSION)
on on Not
Assigned
Table 5. Product Mode Configuration jumper settings.
NEED CLOSEUP PICTURE OF JUMPERS HERE