User's Manual

Octopus ATM Defense System
Installation and Operation Guide
PageT2
12. Pressing the POST button while in Test mode releases the unit from test mode.
Procedure:
Cassette staining units should be complete and MCU position testing complete per installation instructions.
1. Insure that all cassette staining units have their ink blocks disconnected. The ink block wiring must be
replaced with a shorting shunt that was provided when the unit shipped. Without the shorting bars the
CSUs will not pass self-test !
2. Install all used sensor inputs to MCU. (Use caution to make sure polarity is correct as the system uses a
common ground.)
SENSOR INPUT
LOCATION
Octopus Level II
(Canadian)
Octopus Level III
(US)
Octopus Level V
(Brazil)
ATM DOOR
Terminal Block pin 5 &
Ground pin 6.
Or
Array Cable pin 5 &
Ground pin 4
Required.
Connect to door contact
switch.
Required.
Connect to door contact
switch.
Required.
Connect to door contact
Switch.
Generic NC input # 2
Terminal Block pin 1 &
Ground pin 2.
Required
Connect to bolt position
indicator.
Required
Will cause BIST error on
POST.
Required.
Connect to ATM alarm suite,
alerts system only.
Generic NC input # 1
Array Cable pin 7 &
Ground pin 4
Optional
Does not cause BIST error
on POST.
Optional
Does not cause BIST error
on POST.
Required.
Connect to ATM alarm suite,
alerts the system.
Generic NO input # 2
Array Cable pin 2 &
Ground pin 4
Optional
Does not cause BIST error
on POST.
Optional
Does not cause BIST error
on POST.
Required.
Connect to ATM alarm suite,
alerts the system.
Generic NO input # 1
Array Cable pin 8 &
Ground pin 4
Optional.
Does not cause BIST error
on POST.
Optional.
Does not cause BIST error
on POST.
Required.
Connect to ATM alarm suite,
alerts the system.
Power Loss input
Terminal Block pin 3 &
Ground pin 2.
Or
Array Cable pin 3 &
Ground pin 4
Optional.
Does not cause BIST error
on POST.
Optional.
Does not cause BIST error
on POST.
Required.
Connect to ATM alarm suite
power output +5 VDC, alerts
the system.
All Safe signal
Array Cable pin 6 &
Ground pin 4
Optional.
Does not cause BIST error
on POST.
Optional.
Does not cause BIST error
on POST.
Required.
Connect to authorized
opening detection, resets the
system only.
Manual Fire NC/Breach
Terminal Block pin 4 &
Ground pin 2 or 6.
Or
Array Cable pin 1 &
Ground pin 4
Optional.
Will cause BIST error on
POST.
Required.
Will cause BIST error on
POST.
Required.
Terminal Block or Sensor
Array Cable connected to
breach sensor detection, fires
the system. If unused
Terminal block pin 4 must be
shorted to ground with a buss
strap.
Table 1. External sensor input selection table.
Required means that the input must be provided for either by installation of the sensor or using the
provided buss-bar to short the contacts. Required contacts are monitored by the BIST errors during
POST.
Optional means that input may be used; however, no BIST error will occur if contact is mis-wired.
All inputs are testable using the test mode.